Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
Parameter
Min
0
Max
14
Unit
Supply Voltage
V
V
Input Voltage Range
-V -0.5V
s
+V +0.5V
s
Reliability Information
Parameter
Min
-65
Typ
Max
Unit
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
6-Lead SOT23
150
150
260
°C
°C
°C
177
100
°C/W
°C/W
8-Lead SOIC
Notes:
Package thermal resistance (q ), JDEC standard, multi-layer test boards, still air.
JA
ESD Protection
Product
SOT23-6
Human Body Model (HBM)
2kV
2kV
Charged Device Model (CDM)
Recommended Operating Conditions
Parameter
Min
Typ
Max
Unit
Operating Temperature Range (CLC1002I)
Operating Temperature Range (CLC1002A)
Supply Voltage Range
-40
-40
4
+85
+125
12
°C
°C
V
©2007-2013 Exar Corporation
3/17
Rev 1G