Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
C
omlinear
CLC1001
Ultra-Low Noise Amplifier
Parameter
Supply Voltage
Input Voltage Range
Min
0
-V
s
-0.5V
Max
14
+V
s
+0.5V
Unit
V
V
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
6-Lead SOT23
8-Lead SOIC
Notes:
Package thermal resistance (q
JA
), JDEC standard, multi-layer test boards, still air.
Min
-65
Typ
Max
150
150
260
Unit
°C
°C
°C
°C/W
°C/W
177
100
ESD Protection
Product
Human Body Model (HBM)
Charged Device Model (CDM)
SOT23-6
2kV
2kV
Rev 1G
Recommended Operating Conditions
Parameter
Operating Temperature Range
Supply Voltage Range
Min
-40
4
Typ
Max
+125
12
Unit
°C
V
©2007-2013 Exar Corporation
3/17