PD70-01C/TR10
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
NO. Item
Test Conditions
Test Hours/ Sample Failure
Ac/Re
Cycles
Sizes
22pcs
22pcs
Judgement
Criteria
TEMP.:260℃±5℃
1 REFLOW
6Mins
0/1
0/1
5secs
IL≦L×0.8
H : 100℃
15mins
2 Temperature Cycle
50Cycles
5mins
L:Lower
Specification
Limit
L : -40℃
15mins
H :+100℃
5mins
3 Thermal Shock
50Cycles
22pcs
0/1
10secs
5mins
L :-10℃
TEMP.:+100℃
4 High Temperature
Storage
1000hrs
1000hrs
22pcs
22pcs
0/1
0/1
TEMP.:-40℃
5 Low Temperature
Storage
6 DC Operating Life VR=5V
1000hrs
1000hrs
22pcs
22pcs
0/1
0/1
85℃ / 85% R.H
7 High Temperature/
High Humidity
Everlight Electronics Co., Ltd.
http:\\www.everlight.com
Rev 1
Page: 8 of 10
Device No:DTD-700-179
Prepared date:08-26-2005
Prepared by:JAINE TSAI