EVERLIGHT ELECTRONICS CO.,LTD.
IRM-H2xxT/TR2 SERIES
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Reflow Terms: JEDEC Level 4 Specification
Drying; Temp.:125℃ 24hrs Æ Moisture 30℃ / 60% RH 96hrs Æ Reflow Temp.: 260℃±5℃
10sec, 3 times
Note:
1. Not sooner than 15 minutes and not longer than 4 hours after removal from the
temperature/humidity chamber.
2. The time between reflow shall be 5 minutes minimum and 60 minutes maximum.
Failure Judgement Samples(n)
Test Items
Test Conditions
Criteria
Defective(c)
1 cycle:-25℃
+85℃
Temperature cycle
High temperature test
(30min)(5min)(30min)
300 cycle test
n=76,c=0
L0≦ L×0.8
L45≦ L×0.8
Temp:+85℃
Vcc:5V
n=76,c=0
n=76,c=0
n=76,c=0
L: Lower
1000hrs
specification limit
Temp:-40℃
Low temperature
storage
*Icc : Operate
Current (mA)
1000hrs
Variation≦±20%:
Ta:85℃,RH:85%
High temperature
High humidity
1000hrs
Everlight Electronics Co., Ltd.
http:\\www.everlight.com
Rev
1
Page: 8 of 12
Device No:DMO-238-408
Prepared date:02-05-2007
Prepared by:Cindy Lin