EUP8020X  
CE Input (Charge Enable)  
Condition #2: Charge voltage below recharge threshold  
(V(RCH)) and timeout fault occurs  
The CE digital input is used to disable or enable the  
charge process. A low-level signal on this pin enables the  
charge and a high-level signal disables the charge and  
places the device in a low-power mode. A high-to-low  
transition on this pin also resets all timers and timer fault  
conditions. Note that this applies to both AC and USB  
charging.  
Recovery method: Under this scenario, the EUP8020X  
applies the I(FAULT) current. This small current is used to  
detect a battery removal condition and remains on as long  
as the battery voltage stays below the recharge threshold.  
If the battery voltage goes above the recharge threshold,  
then the EUP8020X disables the I(FAULT) current and  
executes the recovery method described for condition #1.  
Once the battery falls below the recharge threshold, the  
EUP8020X clears the fault and starts a new charge cycle.  
TTE Input (Timer and Termination Enable)  
A
POR or CE or TTE toggle also clears the fault.  
TTE  
The  
digital input is used to disable or enable the  
fast-charge timer and charge taper detection. A low-level  
signal on this pin enables the fast-charge timer and taper  
timer and a high-level signal disables this feature. Note  
that this applies to both AC and USB charging.  
Thermal shutdown and Protection  
The EUP8020X monitors the junction temperature, TJ, of  
the die and suspends charging if TJ exceeds T(SHTDWN)  
.
Charging resumes when TJ falls below T(SHTDWN) by  
approximately 30 .  
TE Input (Timer Enabled)  
The TE digital input is used to disable or enable the  
fast-charge timer. A low-level signal on this pin enables  
the fast-charge timer and a high-level signal disables this  
feature.  
Note that this applies to both AC and USB charging.  
Timer Fault Recovery  
As shown in Figure 3, EUP8020X provides a recovery  
method to deal with timer fault conditions. The following  
summarizes this method:  
Condition #1: Charge voltage above recharge threshold  
(V(RCH)) and timeout fault occurs  
Recovery method: EUP8020X waits for the battery  
voltage to fall below the recharge threshold. This could  
happen as a result of a load on the battery, self-discharge  
or battery removal. Once the battery falls below the  
recharge threshold, the EUP8020X clears the fault and  
starts a new charge cycle. A POR orCE or TTE toggle  
also clears the fault.  
DS8020X Ver 1.1 June 2006  