欢迎访问ic37.com |
会员登录 免费注册
发布采购

EUP8010C-JIR1 参数 Datasheet PDF下载

EUP8010C-JIR1图片预览
型号: EUP8010C-JIR1
PDF下载: 下载PDF文件 查看货源
内容描述: 线性锂离子/锂聚合物充电器IC,具有集成FET和充电定时器 [Linear Li-Ion/Polymer Charger IC with Integrated FET and Charger Timer]
分类和应用:
文件页数/大小: 12 页 / 292 K
品牌: EUTECH [ EUTECH MICROELECTRONICS INC ]
 浏览型号EUP8010C-JIR1的Datasheet PDF文件第4页浏览型号EUP8010C-JIR1的Datasheet PDF文件第5页浏览型号EUP8010C-JIR1的Datasheet PDF文件第6页浏览型号EUP8010C-JIR1的Datasheet PDF文件第7页浏览型号EUP8010C-JIR1的Datasheet PDF文件第8页浏览型号EUP8010C-JIR1的Datasheet PDF文件第9页浏览型号EUP8010C-JIR1的Datasheet PDF文件第11页浏览型号EUP8010C-JIR1的Datasheet PDF文件第12页  
EUP8010X  
Charge Status Outputs  
Charge Taper Detection, Termination and Recharge  
The open-drain STAT1 and STAT2 outputs indicate  
various charger operations as shown in the following  
table. These status pins can be used to drive LEDs or  
communicate to the host processor. Note that OFF  
indicates the open-drain transistor is turned off.  
The EUP8010X monitors the charging current during the  
voltage regulation phase. Once the taper threshold,  
I(TAPER),is detected the EUP8010X initiates the taper timer,  
t(TAPER). Charge is terminated after the timer expires. The  
resistor connected between the ISET and VSS, RSET  
determines the taper detection level. The V(TAPER) and  
(SET) parameters are specified in the specifications table.  
,
Table 1. Status Pins Summary  
K
CHARGE STATE  
Precharge in progress  
Fast charge in progress  
Charge done  
Charge suspend (temperature)  
Timer fault  
STAT1 STAT2  
V
× K  
(SET)  
(TAPER)  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
ON  
I
=
------------------ (3)  
(TAPER)  
R
SET  
OFF  
OFF  
OFF  
The EUP8010X resets the taper timer in the event that  
the charge current returns above the taper threshold,  
Sleep mode  
I(TAPER)  
.
OFF means the open-drain output transistor on the  
STAT1 and STAT2 pins is in an off state.  
In addition to the taper current detection, the EUP8010X  
terminates charge in the event that the charge current falls  
below the I(TERM) threshold. This feature allows for quick  
recognition of a battery removal condition or insertion of  
a fully charged battery. Note that charge timer and taper  
timer are bypassed for this feature. The resistor  
connected between the ISET and VSS, RSET, determines  
the taper detection level. The V(TERM) and K(SET)  
parameters are specified in the specifications table.  
PG Output  
The open-drain PG (Power Good) indicates when the  
AC adapter is present. The output turns ON when a valid  
voltage is detected. This output is turned off in the sleep  
mode. The PG pin can be used to drive an LED or  
communicate to the host processor.  
V
× K  
(SET)  
(TERM)  
I
=
-------------------- (4)  
(TERM)  
R
SET  
CE Input (Charge Enable)  
The CE digital input is used to disable or enable the  
charge process. A low-level signal on this pin enables the  
charge and a high-level signal disables the charge and  
places the device in a low-power mode. A high-to-low  
transition on this pin also resets all timers and timer fault  
conditions.  
After charge termination, the EUP8010X re-starts the  
charge once the voltage on the OUT pin falls below the  
V(RCH) threshold. This feature keeps the battery at full  
capacity at all times.  
Sleep Mode  
TTE Input (Timer and Termination Enable)  
The EUP8010X enters the low-power sleep mode if  
AC-adapter is removed from the circuit. This feature  
prevents draining the battery during the absence of input  
supply.  
TTE  
The  
digital input is used to disable or enable the  
fast-charge timer and charge taper detection. A low-level  
signal on this pin enables the fast-charge timer and taper  
timer and a high-level signal disables this feature.  
Thermal shutdown and Protection  
The EUP8010X monitors the junction temperature, TJ, of  
the die and suspends charging if TJ exceeds T(SHTDWN)  
.
Charging resumes when TJ falls below T(SHTDWN) by  
approximately 30 .  
DS8010X Ver 1.2 June 2007  
10