ModSTACK
Data Sheet: 2B6I 500/800-400G M, S
Preliminary Data
Requirements to the Controller
According EN61800-3
at auxiliary power and
control interface
EMC Protection
1
kV
EMC Environment
Shielding concept with TE
(True Earth) separated
from PE,
HF conform installation
Drive Pulse Time
Block out Time
Over Voltage
Shutdown Reaction
Time
Over Current
Shutdown Reaction
Time
ton_min
tpause
10
10
50
µs
µs
µs
After over voltage
message by
ModSTACK interface
After over current
message by
ModSTACK interface
10
µs
Mechanical Data
Air Velocity
vAir
dV/dtAir
∆pAir
12
2200
700
m/s
m³/h
Pa
ϑAir=20°C
Pair=1013 hPa
Dry- and dustfree,
measured outside of
heatsink.
According DIN 41882
According
Coolingwater
Specification from
eupec for copper tubes
Air Flow/ heatsink
Air Pressure Drop/
heatsink
-
-
Water
dV/dt
Water
l/min
Pa
Flow/ heatsink
Water Pressure Drop/
heatsink
-
∆pWater
Water connection
Dimensions
Mass
Storage Temperature
Range
Operating
Temperature range
(PCB and Capacitor)
Cooling Air Inlet
Temperature
(Heatsink)
Cooling Water Inlet
Temperature
Width x Depth x Height
Approximation
1090
-40
600
101
305
+65
+55
mm
kg
°C
ϑstor
ϑop
Minimal 0 °C for
optional optical
interface
-25 (0)
°C
°C
°C
-25
-40
+40
-
ϑair_inlet
Heatsink temperature >
-25°C
-
ϑwater_
inlet
(Heatsink)
Cooling Air Velocity
(PCB and Capacitor)
Air Pressure
vAir_PCB
pAir
2
m/s
hPa
Standard atmosphere
900
1100
2B6I500-800-400G.doc
4 of 11