EM639165
AVERAGE SUPPLY CURRENT from Vdd
(Ta=0 - 70˚C, VDD=VDDQ=3.3±0.3V,VSS=VSSQ=0V, unless otherwise noted)
Max.
Test Condition
Symbol
Icc1
ITEM
Unit
mA
-75
-8
100
95
tRC=min, tCLK=min
BL=1,IOL=0mA
110
130
100
120
mA
mA
mA
Operating current
CKE=VILmax
tCLK=15ns
Icc2N
Icc2NS
Icc2P
Precharge Standby
current in Non-Power
down mode
Precharge Standby
current in Power down
mode
20
15
2
20
15
2
CKE=VIHmin
CLK=VILmax(fixed)
mA
mA
mA
CKE=VIHmin
tCLK=15ns(Note)
CKE=VIHmin
tCLK=VILmax(fixed)
Icc2PS
Icc3N
1
1
CKE=/CS=VIHmin
tCLK=15ns(Note)
30
30
mA
Active Standby current
Burst current
CKE=VIHmin
tCLK=VILmax(fixed)
Icc3NS
Icc4
20
20
All Bank Active
tCLK = min
BL=4, CL=3, IOL=0mA
160
130
mA
mA
Auto-refresh current
Self-refresh current
tRC=min, tCLK=min
Icc5
Icc6
160
160
Standard
Low-Power
mA
µA
2
2
CKE < 0.2V
800
800
NOTE:
1. Icc(max) is specified at the output open condition.
2. Input signals are changed one time during 30ns.
AC OPERATING CONDITIONS AND CHARACTERISTICS
(Ta=0 - 70˚C, VDD=VSSQ=3.3±0.3V,VSS=VSSQ=0V, unless otherwise noted)
Parameter
Test Conditions
Unit
V
Max.
Min.
2.4
Symbol
VOH (DC)
VOL (DC)
IOZ
High-Level Output Voltage (DC)
Low-level Output Voltage (DC)
Off-state Output Current
Input Current
IOH=-2mA
0.4
10
10
IOL= 2mA
V
µA
-10
-10
Q floating VO= 0 -- VDDQ
µA
II
VIH = 0 -- VDDQ +0.3V
Preliminary
Rev 1.0 Feb. 2001
30