EtronTech
WE#
Input
LDQM,
UDQM
DQ0-DQ15
NC/RFU
V
DDQ
Input
EM638165
Write Enable:
The WE# signal defines the operation commands in conjunction
with the RAS# and CAS# signals and is latched at the positive edges of CLK.
The WE# input is used to select the BankActivate or Precharge command and
Read or Write command.
Data Input/Output Mask:
Controls output buffers in read mode and masks
Input data in write mode.
Input /
Output
-
Supply
Data I/O:
The DQ0-15 input and output data are synchronized with the positive
edges of CLK. The I/Os are maskable during Reads and Writes.
No Connect:
These pins should be left unconnected.
DQ Power:
Provide isolated power to DQs for improved noise immunity.
( 3.3V± 0.3V )
V
SSQ
Supply
DQ Ground:
Provide isolated ground to DQs for improved noise immunity.
(0V)
Power Supply:
+3.3V
±
0.3V
Ground
V
DD
V
SS
Supply
Supply
Preliminary
4
Rev 0.6
Feb. 2001