Operate in API mode
Frame descriptions
The device will continue to operate at the current baud rate until the change is applied with a
subsequent AC command.
The corresponding Local AT Command Response - 0x88 with a matching Frame ID will indicate
whether the parameter change succeeded.
7E 00 05 09 53 42 44 07 16
Frame type
0x09
Frame ID
0x53
AT command
0x4244
Parameter value
0x07
Request
Matches response
"BD"
7 = 115200 baud
Query local command parameter
Query the temperature of the module (TP command).
The corresponding Local AT Command Response - 0x88 frame with a matching Frame ID will return
the temperature value.
7E 00 04 09 17 54 50 3B
Frame type
0x09
Frame ID
0x17
AT command
0x5450
Parameter value
(omitted)
Request
Matches response
"TP"
Query the parameter
XBee/XBee-PRO S2C 802.15.4 RF Module User Guide
121