24C32 / 24C64
AC Electrical Characteristics
。
。
Applicable over recommended operating range from T
100 pF (unless otherwise noted)
A
= -40 C to +85 C, VCC = +1.8V to +5.5V, CL = 1 TTL Gate and
1.8-volt
5.0-volt
Typ.
-
Parameter
Symbol
Units
Min.
-
Typ.
-
Max.
400
Min.
-
Max.
1000
Clock Frequency, SCL
Clock Pulse Width Low
Clock Pulse Width High
Noise Suppression Time
Clock Low to Data Out Valid
f
SCL
LOW
HIGH
kHz
t
1.2
0.6
-
-
-
-
-
-
-
0.6
0.4
-
-
-
-
-
-
-
s
s
s
s
t
t
I
50
0.9
40
0.55
0.05
t
AA
0.05
Time the bus must be free before
a new transmission can start
t
BUF
1.2
-
-
0.5
-
-
s
Start Hold Time
t
HD.STA
SU.STA
HD.DAT
SU.DAT
0.6
0.6
0
-
-
-
-
-
-
-
-
-
-
-
0.25
-
-
-
-
-
-
-
-
-
-
-
s
Start Setup Time
Data In Hold Time
Data In Setup Time
Inputs Rise Time(1)
Inputs Fall Time(1)
Stop Setup Time
Data Out Hold Time
Write Cycle Time
t
-
0.25
-
s
t
-
0
-
s
t
100
-
-
0.3
300
-
100
-
0.3
100
-
ns
t
R
-
s
t
F
-
-
0.25
50
-
ns
t
SU.STO
DH
WR
0.6
50
-
s
ns
t
-
-
t
5
5
ms
。
5.0V, 25 C, Byte Mode
Endurance
1M
-
-
-
Write Cycles
Note
1. This parameter is characterized and is not 100% tested.
2. AC measurement conditions:
RL (connects to VCC): 1.3 k (2.5V, 5V), 10 k (1.8V)
Input pulse voltages: 0.3 VCC to 0.7 VCC
Input rise and fall time: 50 ns
Input and output timing reference voltages: 0.5 VCC
The value of R should be concerned according to the actual loading
L
on the user's system.
BEIJING ESTEK ELECTRONICS CO.,LTD
10