PTB 20038
Electrical Characteristics
Characteristic
Breakdown Voltage C to E
Breakdown Voltage C to E
Breakdown Voltage E to B
DC Current Gain
(100% Tested)
e
Conditions
I
B
= 0 A, I
C
= 100 mA
V
BE
= 0 V, I
C
= 100 mA
I
C
= 0 A, I
E
= 5 mA
V
CE
= 5 V, I
C
= 1 A
Symbol
V(
BR)CEO
V(
BR)CES
V(
BR)EBO
h
FE
Min
25
55
3.5
20
Typ
30
70
5
50
Max
—
—
—
100
Units
Volts
Volts
Volts
—
RF Specifications
(100% Tested)
Characteristic
Gain
(V
CC
= 25 Vdc, Pout = 25 W, I
CQ
= 100 mA, f = 900 MHz)
Collector Efficiency
(V
CC
= 25 Vdc, Pout = 25 W, I
CQ
= 100 mA, f = 900 MHz)
Gain
(V
CC
= 25 Vdc, Pout = 10 W, I
CQ
= 100 mA, f = 900 MHz)
Collector Efficiency
(V
CC
= 25 Vdc, Pout = 10 W, I
CQ
= 100 mA, f = 900 MHz)
Load Mismatch Tolerance
(V
CC
= 25 Vdc, Pout = 10 W, I
CQ
= 100 mA,
f = 900 MHz—all phase angles at frequency of test)
Symbol
G
pe
η
C
G
pe
η
C
Ψ
Min
9.0
50
10
35
—
Typ
10.0
—
11
—
—
Max
—
—
—
—
30:1
Units
dB
%
dB
%
—
Typical Performance
Efficiency vs. Frequency
80
70
60
(as measeured in a broadband circuit)
Pout = 25 W
Efficiency (%)
50
40
30
20
10
0
840
Pout = 10 W
V
CC
= 25 V
I
CQ
= 100m A
Circuit Tuned for
25 W Load Line
855
870
885
900
915
Frequency (MHz)
Ericsson Components
RF Power Products
675 Jarvis Drive
Morgan Hill, CA 95037 USA
Telephone: 408-778-9434
1-877-GOLDMOS
(1-877-465-3667)
e-mail: rfpower@ericsson.com
www.ericsson.com/rfpower
Specifications subject to change without notice.
LF
© Ericsson Components AB 1994
EUS/KR 1301-PTB 20038 Uen Rev. D 09-28-98
2