Operating Frequency (typ)  
EMC Specifications  
102  
The PKF power module is mounted on a double sided printed circuit  
board (PB) with groundplane during EMC measurements. The  
fundamental switching frequency is 485 kHz 15% @ IO =  
(0.5...1.0) × IOmax.  
101  
100  
99  
Conducted EMI (input terminals)  
98  
97  
96  
-40  
-20  
0
+20  
+40  
+60  
+80 +100  
Pin temperature (°C)  
550  
72 V  
48 V  
500  
450  
400  
350  
300  
38 V  
PKF series typical conducted EMI performance  
Test set up  
0
20  
40  
60  
80  
100  
120  
140  
Load (%)  
The operating frequency vs. load and input voltage (72V, 48V and 38V).  
Tp= +25°C.  
Radiated EMS (Electro-Magnetic Fields)  
Radiated EMS is measured according to test methods in IEC  
Standard publ. 801-3. No deviation outside the VO tolerance band  
will occur under the following conditions:  
The PKF meets class A in VDE 0871/0878, FCC Part 15J, and CISPR 22  
(EN 55022).  
Frequency range  
0.01...200 MHz  
200...1,000 MHz  
1...12 GHz  
Voltage level  
3 Vrms/m  
3 Vrms/m  
10 Vrms/m  
Radiated EMI  
ESD  
Radiated emission of electromagnetic fields is measured at 10 m  
distance.  
Electro Static Discharge is tested according to IEC publ. 801-2. No  
destruction will occur if the following voltage levels are applied to  
any of the terminal pins:  
30...100 MHz  
100...200 MHz  
200...230 MHz  
230...1,000 MHz  
1...10 GHz  
60 dB mV/m  
40 dB mV/m  
30 dB mV/m  
35 dB mV/m  
46 dB mV/m  
Test  
Voltage level  
4 kV  
Air discharge  
Contact discharge  
2 kV  
EFT  
Electrical Fast Transients on the input terminals could affect the  
output voltage regulation causing functional errors on the Printed  
Board Assembly (PBA). The PKF power module withstand EFT  
levels of 0.5 kV keeping VO within the tolerance band and 2.0 kV  
without destruction. Tested according to IEC publ. 801-4.  
Conducted EMS  
Electro Magnetic Susceptibility is measured by injection of elec-  
trical disturbances on the input terminals. No deviation outside  
the VO tolerance band will occur under the following conditions:  
Frequency range  
0.15...300 MHz  
Voltage level  
1.0 Vrms  
Output Ripple & Noise (VOac)  
The signal is amplitude modulated with 1 kHz/80% and applied  
both differential and common mode.  
Output ripple is measured as the peak to peak voltage of the funda-  
mental switching frequency.  
EN/LZT 146 33 R1A (Replaces EN/LZT 137 09 R7) © Ericsson Microelectronics AB, June 2000  