General
Absolute Maximum Ratings
Characteristics
T
C
T
S
V
I
V
ISO
V
tr
V
RC
V
adj
Case temperature at full output power
Storage temperature
Continuous input voltage
Isolation voltage
(input to output test voltage)
Transient input energy
Remote control voltage pin 10, 11 ref. to pin 18
Output adjust voltage pin 8, 9 ref. to pin 18
–5
–5
min
–45
–55
–0.5
1,500
0.01
V
I
+40
max
+100
+125
+40
Unit
°C
°C
V dc
V dc
Ws
V dc
V dc
Stress in excess of Absolute Maximum
Ratings may cause permanent damage.
Absolute Maximum Ratings, sometimes
referred to as no destruction limits, are
normally tested with one parameter at a
time exceeding the limits of Output data
or Electrical Characteristics. If exposed to
stress above these limits, function and
performance may degrade in an unspeci-
fied manner.
Input
T
C
< T
Cmax
unless otherwise specified
Characteristics
V
I
V
Ioff
V
Ion
C
I
P
Ii
P
RC
Input voltage range
1)
Turn-off input voltage
Turn-on input voltage
Input capacitance
Input idling power
Input stand-by power
I
O
= 0, T
C
= –30…+ 85 °C
T
C
= –30…+ 85 °C,
RC connected to pin 18
(V
I
= 24V)
(V
I
= 27V)
(V
I
= 24V)
(V
I
= 27V)
See typical characteristics
See typical characteristics
Conditions
min
18
16
typ
max
36
Unit
V
V
V
mF
NOTES:
1)
16.8
18.3
2.4
18
19
360
300
25
40
mW
mW
The power modules will operate down to
V
I
£18
V, when V
I
decreases, but will turn on
at V
I
£19
V, when V
I
increases (see also
Operating Information.
The test is applicable for through-hole
versions.
2)
Environmental Characteristics
Characteristics
Vibration
(Sinusoidal)
JESD 22-B103
(IEC 68-2-6 F
c
)
Test procedure & conditions
Frequency
Amplitude
Acceleration
Number of cycles
Frequency
Acceleration density
spectrum
Duration
Reproducability
Peak acceleration
Shock duration
Temperature
Number of cycles
Temperature
Humidity
Duration
Temperature, solder
Duration
Duration
Temperature
Concentration
10…500 Hz
0.75 mm
10 g
10 in each axis
10…500 Hz
0.5 g
2
/Hz
10 min in 3 directions
medium (IEC 62-2-36)
200 g
3 ms
–40°C…+125°C
500
85°C
85% RH
1000 hours
260°C
10…13 s
96 h
35°C
5%
Random
vibration
MIL-STD-883
Method 2026
(IEC 68-2-34 E
d
)
Shock
(Half sinus)
Temperature
change
Accelerated
damp heat
Solder
resistability
2)
Aggressive
environment
JESD 22-B104
(IEC 68-2-27 E
a
)
JESD 22-A104
(IEC 68-2-14 N
a
)
JESD 22-A101
(IEC 68-2-3 C
a
with bias)
JESD 22-B106
(IEC 68-2-20 T
b
1A)
IEC 68-2-11 K
a
2