Ericsson Internal
E
EAB/FJB/GMF Oscar Persson
PRODUCT SPECIFICATION
1 (10)
Prepared (also subject responsible if other)
No.
2/1301 BMR 662 Uen
4
Technical Specification
Approved
Checked
Date
Rev
Reference
EN/LZT 146 420 R2A May 2010
PKB 4000A series Direct Converters
Input 38-72 V, Output up to 30 A / 125 W
EAB/FJB/GMF [Natalie Johansson]
(MICRF)
2010-05-04
B
© Ericsson AB
Absolute Maximum Ratings
Characteristics
min
-40
typ
max
+125
+110
+80
2250
100
Unit
°C
°C
V
TP1
TS
Operating Temperature (see Thermal Consideration section)
Storage temperature
-55
VI
Input voltage
-0.5
Viso
Vtr
Isolation voltage (input to output test voltage)
Input voltage transient (tp 100 ms)
Vdc
V
Positive logic option
Negative logic option
0
0
40
V
Remote Control pin voltage
(see Operating Information section)
VRC
Vadj
40
V
Adjust pin voltage (see Operating Information section)
-0.5
2xVoi
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits in the Electrical Specification. If exposed to stress above these limits, function and performance
may degrade in an unspecified manner.
Fundamental Circuit Diagram
Primary
Secondary
+ In
+ Out
+ Sense
Primary
Driver
Secondary
Driver
- Sense
- Out
Control and
Supervision
Vadj
Bias supply
and OTP
Isolated
Feedback
RC
- In