E
5
Technical Specification  
EN/LZT 146 420 R3A March 2014  
© Ericsson AB  
PKB 4000A series Direct Converters  
Input 36-72 V, Output up to 30 A / 125 W  
3.3V, 30A /99W Electrical Specification  
PKB 4910A PI  
TP1 = -30 to +90ºC, VI = 36 to 72 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: TP1 = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions.  
Additional Cin = 33 µF. See Operating Information section for selection of capacitor types.  
Characteristics  
Conditions  
min  
36  
typ  
max  
Unit  
V
VI  
Input voltage range  
72  
32  
35  
VIoff  
VIon  
CI  
Turn-off input voltage  
Turn-on input voltage  
Internal input capacitance  
Output power  
Decreasing input voltage  
Increasing input voltage  
30  
31  
34  
V
33  
V
5.7  
μF  
W
PO  
0
99  
50 % of max IO  
92.4  
91.0  
92.7  
91.0  
9.8  
max IO  
η
Efficiency  
%
50 % of max IO, VI = 48 V  
max IO, VI = 48 V  
max IO  
Pd  
Pli  
PRC  
fs  
Power Dissipation  
Input idling power  
Input standby power  
Switching frequency  
14  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100 % of max IO  
1.8  
0.1  
W
162  
180  
198  
kHz  
Output voltage initial setting and  
accuracy  
VOi  
TP1 = +25°C, VI = 53 V, IO = 30 A  
3.23  
3.30  
3.37  
3.63  
V
V
See operating information (see Note  
1)  
Output adjust range  
2.64  
3.2  
Output voltage tolerance band  
Line regulation  
0-100 % of max IO  
max IO  
3.4  
±10  
±10  
V
VO  
±3  
±5  
mV  
mV  
Load regulation  
VI = 53 V, 0-100 % of max IO  
Load transient  
voltage deviation  
VI = 53 V, Load step 25-75-25 % of  
max IO, di/dt = 1 A/μs  
See Note 2  
Vtr  
ttr  
±200  
40  
±350  
mV  
µs  
Load transient recovery time  
Ramp-up time  
tr  
8
ms  
(from 10−90 % of VOi)  
0-100 % of max IO  
Start-up time  
(from VI connection to 90 % of VOi)  
ts  
tf  
12  
ms  
max IO  
IO = 0 A  
max IO  
50  
5
μs  
s
VI shut-down fall time  
(from VI off to 10 % of VO)  
RC start-up time  
12  
ms  
tRC  
max IO  
37  
5
μs  
s
RC shut-down fall time  
(from RC off to 10 % of VO)  
IO = 0 A  
IO  
Output current  
0
30  
A
Ilim  
Isc  
Current limit threshold  
Short circuit current  
TP1 < max TP1  
40  
45  
A
TP1 = 25ºC, see Note 3  
A
Cout  
Recommended Capacitive Load TP1 = 25ºC, see Note 4  
0
3000  
120  
µF  
See ripple & noise section,  
VOac  
Output ripple & noise  
max IO, VOi  
60  
mVp-p  
V
TP1 = +25°C, VI = 53 V, 0-100 % of  
max IO  
OVP  
Over voltage protection  
3.8  
4.3  
4.8  
Note 1: At trim-up, the minimum VIn/Vout ratio must be kept, i.e. 5 % trim up require VIn > 37.8 V  
Note 2: 3000 uF; ESR value 5 mΩ  
Note 3: Constant current Vo < 0.5 V  
Note 4: See Operating Information Section  