Technical Specification  
EN/LZT 146 394R5DOctober 2013  
PKB 4000 series  
© Ericsson AB  
DC/DC converters, Input 36-75 V, Output 30 A/90 W  
Operating information continued  
Thermal Consideration  
Parallel Operation  
General  
Two converters may be paralleled for redundancy if the total  
power is equal or less than PO max. It is not recommended to  
parallel the converters without using external current sharing  
circuits.  
The converters are designed to operate in different thermal  
environments and sufficient cooling must be provided to  
ensure reliable operation.  
Cooling is achieved mainly by conduction, from the pins to  
the host board, and convection, which is dependant on the  
airflow across the converter. Increased airflow enhances the  
cooling of the converter.  
See Design Note 006 for detailed information.  
Remote Sense  
The Output Current Derating graph found in the Output  
section for each model provides the available output current  
vs. ambient air temperature and air velocity at Vin = 53 V.  
The DC/DC converters have remote sense that can be used  
to compensate for voltage drops between the output and the  
point of load. The sense traces should be located close to the  
PCB ground layer to reduce noise susceptibility. The remote  
sense circuitry will compensate for up to 10% voltage drop  
between output pins and the point of load.  
The DC/DC converter is tested on a 254 x 254 mm,  
35 µm (1 oz), 8-layer test board mounted vertically in a wind  
tunnel with a cross-section of 305 x 305 mm.  
If the remote sense is not needed +Sense should be  
connected to +Out and -Sense should be connected to -Out.  
Proper cooling of the DC/DC converter can be verified by  
measuring the temperature at positions P1, P2 and P3. The  
temperature at these positions should not exceed the max  
values provided in the table below.  
Over Temperature Protection (OTP)  
The converters are protected from thermal overload by the  
control IC.  
Note that the max value is the absolute maximum rating  
(non destruction) and that the electrical Output data is  
guaranteed up to Tref +90°C.  
When Tref as defined in thermal consideration section  
exceeds 135°C the converter will shut down. The DC/DC  
converter will make continuous attempts to start up (non-  
latching mode) and resume normal operation automatically  
when the temperature has dropped >10°C below the  
temperature threshold.  
See Design Note 019 for further information.  
Position  
P1  
Device  
Pcb  
Designation  
max value  
110º C  
Over Voltage Protection (OVP)  
P2  
P3  
Mosfet  
Mosfet  
120º C  
120º C  
The converters have output over voltage protection that will  
shut down the converter in over voltage conditions. The  
converter will make continuous attempts to start up (non-  
latching mode) and resume normal operation automatically  
after removal of the over voltage condition.  
Tref  
Over Current Protection (OCP)  
The converters include current limiting circuitry for protection  
at continuous overload.  
The output voltage will decrease towards zero for output  
currents in excess of max output current (max IO). The  
converter will resume normal operation after removal of the  
overload. The load distribution should be designed for the  
maximum output short circuit current specified.  