欢迎访问ic37.com |
会员登录 免费注册
发布采购

PKB4318NPINB 参数 Datasheet PDF下载

PKB4318NPINB图片预览
型号: PKB4318NPINB
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, ROHS AND REACH COMPLIANT, EIGHTH BRICK PACKAGE-8]
分类和应用:
文件页数/大小: 46 页 / 1697 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PKB4318NPINB的Datasheet PDF文件第13页浏览型号PKB4318NPINB的Datasheet PDF文件第14页浏览型号PKB4318NPINB的Datasheet PDF文件第15页浏览型号PKB4318NPINB的Datasheet PDF文件第16页浏览型号PKB4318NPINB的Datasheet PDF文件第18页浏览型号PKB4318NPINB的Datasheet PDF文件第19页浏览型号PKB4318NPINB的Datasheet PDF文件第20页浏览型号PKB4318NPINB的Datasheet PDF文件第21页  
E
17  
Technical Specification  
EN/LZT 146 394R5DOctober 2013  
PKB 4000 series  
© Ericsson AB  
DC/DC converters, Input 36-75 V, Output 30 A/90 W  
2.5 V/25 A Electrical Specification  
PKB4619 PINB  
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.  
Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions.  
Additional Cin = 0µF and Cout = 0µF. See Operating Information section for selection of capacitor types.  
Characteristics  
Conditions  
min  
36  
typ  
max  
Unit  
V
VI  
Input voltage range  
75  
32  
35  
VIoff  
VIon  
CI  
Turn-off input voltage  
Turn-on input voltage  
Internal input capacitance  
Output power  
Decreasing input voltage  
Increasing input voltage  
30  
31  
34  
V
33  
V
3.35  
µF  
PO  
Output voltage initial setting  
50 % of max IO  
0
62.5  
9.4  
W
89.6  
89.5  
90.0  
89.5  
7.4  
max IO  
η
Efficiency  
%
50 % of max IO, VI = 48 V  
max IO, VI = 48 V  
max IO  
Pd  
Pli  
Power Dissipation  
Input idling power  
Input standby power  
Switching frequency  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100 % of max IO  
2.1  
PRC  
fs  
0.118  
198  
W
kHz  
Output voltage initial setting and  
accuracy  
VOi  
Tref = +25°C, VI = 53 V, IO = 15 A  
2.45  
2.5  
2.55  
V
Output adjust range  
Output voltage tolerance band  
Idling voltage  
See operating information  
10-100 % of max IO  
2.00  
2.40  
2.45  
2.75  
2.60  
2.55  
10  
V
V
VO  
IO = 0 A  
V
Line regulation  
max IO  
3
3
mV  
mV  
Load regulation  
VI = 53 V, 0-100 % of max IO  
10  
Load transient  
voltage deviation  
Vtr  
ttr  
tr  
±300  
50  
±400  
200  
17  
mV  
µs  
VI = 53 V, Load step 25-75-25 % of  
max IO, di/dt = 1 A/µs  
Load transient recovery time  
Ramp-up time  
(from 1090 % of VOi)  
3
6
11  
ms  
10-100 % of max IO  
Start-up time  
(from VI connection to 90 % of VOi)  
ts  
tf  
14  
21  
ms  
max IO  
IO = 0 A  
max IO  
0.062  
8
ms  
VI shut-down fall time  
(from VI off to 10 % of VO)  
s
RC start-up time  
12  
ms  
ms  
s
tRC  
max IO  
0.13  
8
RC shut-down fall time  
(from RC off to 10 % of VO)  
IO = 0 A  
IO  
Output current  
0
25  
35  
41  
A
Ilim  
Isc  
Current limit threshold  
Short circuit current  
Tref < max Tref  
Tref = 25ºC,  
27  
31  
37  
A
A
See ripple & noise section,  
max IO, VOi  
VOac  
Output ripple & noise  
40  
80  
mVp-p  
V
Tref = +25°C, VI = 53 V, 0-100 % of  
OVP  
Over voltage protection  
2.9  
3.1  
4.0  
max IO  
 复制成功!