 浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第1页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第3页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第4页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第5页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第6页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第7页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第8页浏览型号PKB4207LBPIMLB/B的Datasheet PDF文件第9页  
E
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
2 (4)
Prepared (also subject responsible if other)
SEC/S Marshall Wang
Checked
BPOW 00201-1/1301 Uen
Date
Rev
Technical Specification
Reference
May
2013
© Ericsson AB
2
PKB 4000B series
Intermediate Bus Converters
2013-02-07
Input 36-75 V, Output up to
40
A / 252 W
Ordering Information
Product program
PKB 4201B PI
PKB 4204B PI
PKB 4207LB PI
PKB 4207KB PI
Output
5 V, 40 A / 200 W
12 V, 20 A / 240 W
13 V, 20 A / 252 W
14 V, 10 A / 140 W
EN/LZT 146
384
R4A
B
Z
MTBF (mean value) for the PKB-B series = 3.4 Mh.
MTBF at 90% confidence level = 2.9 Mh
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2011/65/EU and have a
maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
n
6
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products are found in the Statement of
Compliance document.
Ericsson Power Modules fulfills and will continuously fulfill
all its obligations under regulation (EC) No 1907/2006
concerning the registration, evaluation, authorization and
restriction of chemicals (REACH) as they enter into force
and is through product materials declarations preparing for
the obligations to communicate information on substances
in the products.
Quality Statement
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, Six Sigma, and SPC are intensively in use to
boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of the products.
Warranty
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose
(including, but not limited to, use in life support
applications, where malfunctions of product can cause
injury to a person’s health or life).
© Ericsson AB 2013
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
Product number and Packaging
PKB4XXXB PI n
1
n
2
n
3
n
4
n
5
n
6
Options
n
1
n
2
n
3
n
4
Mounting
Remote Control logic
Baseplate
Increased stand-off
Pin length
Delivery package information
Options
n
1
n
2
P
n
3
HS
n
4
n
5
LA
LB
n
6
/B
M
Description
PI
SI
Through hole
Surface mount
Negative *
Positive
Open frame *
Baseplate
Increased stand-off
5.30 mm *
3.69 mm
4.57 mm
Tray
n
5
Example: a standard through hole, positive logic, baseplate
with increased stand-off short pin product would be
PKB4204BPIPHSMLA.
* Standard variant (i.e. no option selected).
General Information
Reliability
The failure rate (
) and mean time between failures
(MTBF= 1/
) is calculated at max output power and an
operating ambient temperature (T
A
) of +40°C. Ericsson
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to
calculate the mean steady-state failure rate and standard
deviation (
).
Telcordia SR-332 Issue 2 also provides techniques to
estimate the upper confidence levels of failure rates based
on the mean and standard deviation.
Mean steady-state failure
Std. deviation,
293 nFailures/h
37.1 nFailures/h