PGR 203 12
Optical and Electrical AC Characteristics
Electrical and optical characteristics over recommended operating conditions, unless otherwise noted.
Parameters are met by an individual differential output.
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
Minimum bandwidth (-3dB)
Bandwidth variation
Gain peaking
Sensitivity: Pf @ BER = 1·10
-10
Overload: Pf @ BER = 1·10
-10
Output signal swing
AC transimpedance
Logic sense
-30dBm < Pf < -6dBm
-30dBm < Pf < -6dBm
BW
max
=
α·BW
min
BW
min
α
δ
Peak
Pr
2.0
2.5
1.2
0
-34
GHz
1.3
2
-32
dB
dBm
dBm
800
mV
P-P
2.5 Gbps NRZ,
PRBS 2
23
-1,
λ
=1550 nm
2.5 Gbps NRZ,
Pol
23
PRBS 2 -1,
λ
=1550 nm
-30dBm < Pf < -6dBm
V
Out
R
L
= 50Ω,
λ
= 1550nm, ER ~10
R
L
= 50Ω, Tz = dV
Out
/l
Ph
, ave
Tz
Data Out
Data_Not Out
-6
30
-3
3.0
kΩ
Light "ON" = Logic "LOW"
Light "ON" = Logic "HIGH"
Optical and Electrical DC Characteristics
Electrical and optical characteristics over recommended operating conditions, unless otherwise noted.
Parameters are met by an individual differential output.
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
DC Power supply current
Power consumption
APD Responsivity
Thermistor, NTC
Optical reflectance
λ
= 1300 nm, M = 12
λ
= 1550 nm, M = 12
T = 25°C
I
dd
I
ss
P
Con
R
13(12)
R
15(12)
R
Th(25)
s11
2925
110
55
0.8
10.5
11.5
3000
140
70
1.1
3075
-27
mA
mA
W
A/W
A/W
dB
Recommended Operating Conditions
Parameter
Optical wavelength
Case temperature
DC Power supply voltage
APD bias
λ
T
Case
V
dd
V
ss
V
Apd
Symbol
Min
Typ
Max
Unit
1250
0
4.7
-5.5
30
5.0
-5.2
1620
70
5.3
-4.9
85
nm
°C
V
V
V
Absolute Maximum Ratings
Parameter
Symbol
Min
Max
Unit
DC Power supply voltage
Storage temperature
V
dd
V
ss
T
Stg
-0.5
-7.0
-40
6.5
0.5
85
V
V
°C
CAUTION:
Stresses outside those listed in ”Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress only rating and operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied.