欢迎访问ic37.com |
会员登录 免费注册
发布采购

PBL386502QNT 参数 Datasheet PDF下载

PBL386502QNT图片预览
型号: PBL386502QNT
PDF下载: 下载PDF文件 查看货源
内容描述: 用户线接口电路 [Subscriber Line Interface Circuit]
分类和应用:
文件页数/大小: 16 页 / 143 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号PBL386502QNT的Datasheet PDF文件第5页浏览型号PBL386502QNT的Datasheet PDF文件第6页浏览型号PBL386502QNT的Datasheet PDF文件第7页浏览型号PBL386502QNT的Datasheet PDF文件第8页浏览型号PBL386502QNT的Datasheet PDF文件第10页浏览型号PBL386502QNT的Datasheet PDF文件第11页浏览型号PBL386502QNT的Datasheet PDF文件第12页浏览型号PBL386502QNT的Datasheet PDF文件第13页  
PBL 386 50/2
15
16
17
18
19
20
21
22
C3
C2
C1
DET
}
C1, C2 and C3 are digital inputs (internal pull-up) controlling the SLIC operating states.
Refer to section "Operating states" for details.
Detector
output. Active low when indicating loop detection and ring trip, active high when indicating
ground key detection.
No
internal
Connection
+5 V power supply.
Programmable Loop Detector
threshold. The loop detection threshold is programmed by a resistor
connected from this pin to AGND.
Programmable Overhead Voltage.
If pin is left open: The overhead voltage is internally set to min 2.7 V in
off-hook and min 1.1 V in On-hook. If a resistor is connected between this pin and AGND: the overhead
voltage can be set to higher values.
Prog. Line Current,
the current limit,reference C in figure 13, is programmed by a resistor connected from
this pin to AGND.
A
Reference,
49.9 kΩ, resistor should be connected from this pin to AGND.
No
internal
Connection
Receive Summing Node.
200 times the AC-current flowing into this pin equals the metallic (transversal)
AC-current flowing from RINGX to TIPX. Programming networks for two-wire impedance and receive gain
connect to the receive summing node. A resistor should be connected from this pin to AGND.
Analog Ground, should be tied together with BGND.
Transmit vf output. The AC voltage difference between TIPX and RINGX, the AC metallic voltage, is
reproduced as an unbalanced GND referenced signal at VTX with a gain of 0.5 (or 0.25, see pin PTG).
The two-wire impedance programming network connects between VTX and RSN.
NC
VCC
PLD
POV
23
24
25
26
PLC
REF
NC
RSN
27
28
AGND
VTX
SLIC Operating States
State
0
1
2
3
4
5
6
7
C3
0
0
0
0
1
1
1
1
C2
0
0
1
1
0
0
1
1
C1
0
1
0
1
0
1
0
1
SLIC operating state
Open circuit
Ringing state
Active state
Active state
Tip open state
Active state
Active reverse
Active reverse
Active detector
-
Ring trip detector (active low)
Loop detector (active low)
Line voltage measurement (note 9)
Loop detector (active low)
Ground key detector (active high)
Loop detector (active low)
Ground key detector (active high)
Table 1. SLIC operating states.
9