PBL 386 30/1
Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Temperature, Humidity
Storage temperature range
Operating temperature range
Operating junction temperature range, Note 1
TStg
TAmb
TJ
-55
-40
-40
+150
+110
+140
°C
°C
°C
Power supply, -40 °C ≤ TAmb ≤ +85 °C
V
V
V
V
CC with respect to A/BGND
BAT2 with respect to A/BGND
Bat with respect to A/BGND, continuous
Bat with respect to A/BGND, 10 ms
VCC
VBat2
VBat
VBat
-0.4
VBat
-75
-80
6.5
0.4
0.4
0.4
V
V
V
V
Power dissipation
Continuous power dissipation at TAmb ≤ +85 °C
PD
VG
1.5
3
W
V
Ground
Voltage between AGND and BGND
Relay Driver
-3
Ring relay supply voltage
BGND+14 V
Ring trip comparator
Input voltage
Input current
VDT, VDR
IDT, IDR
VBat
-5
AGND
5
V
mA
Digital inputs, outputs (C1, C2, DET)
Input voltage
VID
-0.4
-0.4
VCC
VCC
V
V
Output voltage
VOD
TIPX and RINGX terminals, -40 °C < TAmb < +85 °C
TIPX or RINGX current
ITIPX, IRINGX -100
ITIPX, IRINGX -2
ITIPX, IRINGX -5
ITIPX, IRINGX -15
ITIPX, IRINGX -20
ITIPX, IRINGX -20
+100
2
mA
A
TIPX or RINGX current, pulse < 10 ms, t Rep > 10 s
TIPX or RINGX current, pulse < 1 ms, t Rep > 10 s
TIPX or RINGX current, pulse < 10 µs, t Rep > 10 s
TIPX or RINGX current, pulse < 1 µs, t Rep > 10 s
TIPX or RINGX current, pulse < 250 ns, t Rep > 10 s
5
A
15
20
20
A
A
A
Recommended Operating Condition
Parameter
Symbol
Min
Max
Unit
Ambient temperature
TAmb
VCC
VBat
VG
-40
4.75
-58
+85
5.25
-8
°C
V
V
V
V
CC with respect to AGND
Bat with respect to AGND
AGND with respect to BGND
-100
100
mV
Notes
1. The circuit includes thermal protection. Operation at or above 140°C junction temperature may degrade device reliability.