VHF Pair cable, TEL 301 6009
Cable design
- Conductor
- Insulation
- Pair
solid tinned copper wire AWG 26 Ø 0.4 mm
foamskin polyolefin
twisted pairs
- Lay up
concentric stranded pairs.
plastic foil
aluminum foil and braid of tinned copper wires.
- Wrapping
- Screen
- Jacket
flame retardant halogen free thermoplastic compound.
General data
Operating voltage
Operating temp
Bending radius
Flame resistance
Halogen free
100 V
–20 to +75 °C
20 mm (min)
IEC 60332-3- 24 and UL 444 CMR
IEC 60754-2
Marking on jacket
manufacturer, year and week of manufacture,
Ericsson product No., UL and length marking
Grey, black or white according to order information below
Color
Electrical data
Resistance
Capacitance
Impedance
Attenuation
153 mohm/m (max)
46 pF/m (nom)
100±15 ohm (1-125 MHz)
3.2 dB/100 m (max) at 1 MHz
Near end crosstalk loss 62 dB (min) at 1 MHz
Delay skew
45 ns/100m (max)
Transfer impedance
EIC verified
30 mohm/m (30 MHz)
IEC 61156-5, EN 50 288-2-1 and TIA/EIA-568-B
(Exception on attenuation AWG 26 wire )
dB
70
Attenuation
Next
60
50
40
30
20
10
0
Fext
Return loss
f MHz
1
10
100
1000
Order information
Color code
Pair No. Color of core
A-core
Product number
Color of
jacket
Number
Delivery
length/
drum
Cable
Diam.
mm
Net
weight
kg/100m
B-core
blue
of pairs x
conductor
diam
1
2
3
4
White-blue
White-orange orange
White-green green
White-brown brow n
TEL 301 6009/004
Black
White
4x2x0.4
4x2x0.4
2000 m/K6
2000 m/K6
5.0
5.0
3.2
3.2
1/TEL 301 6009/004
2/TEL 301 6009/004
Grey
4x2x0.4
2000 m/K6
5.0
3.2
2/28701-FGC 101 855 Uen Rev E 2012-12-20
Ericsson AB 2010
2 (2)
www.ericsson.com
Cables & Interconnect
Phone: +46 10 7190000