Epson Research and Development  
Page 5  
Vancouver Design Center  
Note  
Mode0.h should be created using the configuration utility 13506CFG. For more infor-  
mation on 13506CFG, see the 13506CFG Configuration Program User Manual, docu-  
ment number X25B-B-001-xx available at www.erd.epson.com.  
6. Open the S1D13506 workspace.  
From the Tornado tool bar, select File->Open Workspace...->Existing->Browse... and  
select the file x:\13506\8bpp\13506.wsp(or x:\13506\16bpp\13506.wsp).  
7. Add support for single line comments.  
The UGL v1.2 display driver source code uses single line comment notation, //,  
rather than the ANSI conventional comments, /* . . . */.  
To add support for single line comments follow these steps:  
a. In the Tornado Workspacewindow, click on the Buildstab.  
b. Expand the 8bpp Builds(or 16bpp Builds) view by clicking on  
the +next to it. The expanded view will contain the item default.  
Right-click on defaultand select Properties.... A properties win-  
dow will appear.  
c. Select the C/C++ compilertab to display the command switches  
used in the build. Remove the -ansiswitch from the line that con-  
tains -g -mpentium -ansi -nostdinc -DRW_MULTI_THREAD.  
(Refer to GNU ToolKit user's guide for details)  
8. Compile the VxWorks image.  
Select the Filestab in the Tornado Workspacewindow.  
Right-click on 8bpp files(or 16bpp files) and select Dependencies.... Click on  
OKto regenerate project file dependencies for All Project files.  
Right-click on 8bpp files(or 16bpp files) and select ReBuild All(vxWorks)to  
build VxWorks.  
9. Copy the VxWorks file to the diskette.  
From a command prompt or through the Windows interface, copy the file  
x:\13506\8bpp\default\vxWorks(or x:\13506\16bpp\default\vxWorks) to the  
bootable disk created in step 4.  
10. Start the VxWorks demo.  
Boot the target PC with the VxWorks bootable diskette to run the UGLDEMO auto-  
matically.  
Wind River UGL v1.2 Display Drivers  