Leaded Varistors
Telecom Series
Maximum ratings
(T
A
= 85
°
C)
Type
SIOV-
S07S60AGS2
S07S95AGS2
Ordering code
V
RMS
V
DC
i
(10
´
)
10/700
m
s
A
1)
V
V
60
85 45
95
125 45
i
max
8/20
m
s
A
1200
1200
W
max
(2 ms)
J
4,8
7,6
P
max
W
0,25
0,25
B72207S0600S212
B72207S0950S212
Characteristics
(T
A
= 25
°
C)
Type
SIOV-
S07S60AGS2
S07S95AGS2
Note
In addition to the telecom varistors listed above, all varistors of the standard series can be used for
telecom applications if the selection criteria are considered.
b
s
V
v
(1 mA)
V
100
150
D
V
v
(1 mA)
%
+18/–1
+10/–2
Max. clamping voltage
v
i
V
A
1)
200
45
270
45
C
typ
(1 kHz)
pF
480
260
Derating
curve
Page
247
247
V/I
char-
acteristic
Page
280
280
1)
ød
e
h
a
1) Seating plane in accordance with IEC 60717
VAR0409-K
Dimensions
Type
SIOV-S07S60AGS2
SIOV-S07S95AGS2
Weight
Size
S07S60
S07S95
approx.
0,6 … 0,8 g
0,6 … 0,8 g
+0,6/-0,1
a
±
1
mm
mm
5,0
1,2
5,0
1,3
b
max
mm
9,0
9,0
s
max
mm
3,3
3,4
h
max
mm
12,0
12,0
I
min
mm
(*)
(*)
d
mm
0,6
0,6
For (*) see chapter
“Taping”,
page 211 ff.
1) The test circuit according to figure 44 in chapter
“Applications”
yields a surge current amplitude of approx. 45 A.
202
04/02