B81123
Y1 / 250 VAC
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k
0
values
Lead spacing
dV/dt in V/µs
k
0
in V
2
/µs
15 mm
3 000
2 100 000
22.5 mm
1 000
700 000
Impedance Z versus frequency f
(typical values)
Please read
Important notes
at the end of this document.
Page 5 of 6