欢迎访问ic37.com |
会员登录 免费注册
发布采购

B59995C0120A070 参数 Datasheet PDF下载

B59995C0120A070图片预览
型号: B59995C0120A070
PDF下载: 下载PDF文件 查看货源
内容描述: PTC热敏电阻器的过流保护 [PTC thermistors for overcurrent protection]
分类和应用: 电阻器
文件页数/大小: 10 页 / 302 K
品牌: EPCOS [ EPCOS ]
 浏览型号B59995C0120A070的Datasheet PDF文件第1页浏览型号B59995C0120A070的Datasheet PDF文件第2页浏览型号B59995C0120A070的Datasheet PDF文件第4页浏览型号B59995C0120A070的Datasheet PDF文件第5页浏览型号B59995C0120A070的Datasheet PDF文件第6页浏览型号B59995C0120A070的Datasheet PDF文件第7页浏览型号B59995C0120A070的Datasheet PDF文件第8页浏览型号B59995C0120A070的Datasheet PDF文件第9页  
Overcurrent protection  
Leaded disks, coated, 12 V, 24 V  
C935 ... C995  
Electrical specifications and ordering codes  
Type  
IR  
IS  
ISmax  
Ir  
RR  
Rmin  
Ordering code  
(V = Vmax  
)
(typ.)  
(V = Vmax  
mA  
)
mA  
mA  
A
C935  
C945  
C955  
C965  
C975  
C985  
C995  
1800  
1300  
850  
600  
450  
250  
120  
3600  
2600  
1700  
1200  
900  
10.0  
8.0  
5.5  
4.3  
3.0  
1.0  
0.7  
170  
115  
80  
70  
60  
0.3  
0.2  
0.3  
0.5  
0.7  
1.1  
2.7  
7.8  
B59935C0120A070  
B59945C0120A070  
B59955C0120A070  
B59965C0120A070  
B59975C0120A070  
B59985C0120A070  
B59995C0120A070  
0.45  
0.8  
1.2  
1.8  
4.6  
500  
240  
45  
25  
13  
Reliability data  
Test  
Standard  
Test conditions  
R25/R25ꢁ  
Electrical endurance, IEC 60738-1  
cycling  
Room temperature, ISmax; Vmax  
Number of cycles: 100  
< 25%  
< 25%  
< 10%  
Electrical endurance, IEC 60738-1  
constant  
Storage at Vmax /Top,max (Vmax  
)
Test duration: 1000 h  
Damp heat  
IEC 60738-1  
IEC 60738-1  
IEC 60738-1  
Temperature of air: 40 °C  
Relative humidity of air: 93%  
Duration: 56 days  
Test according to IEC 60068-2-78  
Rapid change  
of temperature  
T1 = Top,min (0 V), T2 = Top,max (0 V)  
Number of cycles: 5  
Test duration: 30 min  
< 10%  
< 5%  
Test according to IEC 60068-2-14, Test Na  
Vibration  
Frequency range: 10 to 55 Hz  
Displacement amplitude: 0.75 mm  
Test duration: 3 × 2 h  
Test according to IEC 60068-2-6, Test Fc  
Shock  
IEC 60738-1  
IEC 60738-1  
Acceleration: 390 m/s2  
Pulse duration: 6 ms; 6 × 4000 pulses  
< 5%  
Climatic sequence  
Dry heat: T = Top,max (0 V)  
Test duration: 16 h  
< 10%  
Damp heat first cycle  
Cold: T = Top,min (0 V)  
Test duration: 2 h  
Damp heat 5 cycles  
Tests performed according to  
IEC 60068-2-30  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 10