SAW Components
Low-Loss Filter for Mobile Communication
Data Sheet
Characteristics
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
B9403
1960.0 MHz
T
= –20 to +75 ˚C
Z
S
=
50Ω
Z
L
= 150
Ω
|| 18 nH (balanced)
min.
typ.
@ 25˚C
1960
1.6
0,7
1.7
1.7
max.
—
2.6
1.4
2.2
2.2
MHz
dB
dB
Center frequency
Maximum insertion attenuation
1930.0 ... 1990.0
Amplitude ripple
(p-p)
1930.0 ... 1990.0
Input VSWR
1930.0 ... 1990.0
Output VSWR
1930.0 ... 1990.0
MHz
MHz
MHz
f
C
α
max
—
—
∆α
MHz
—
—
—
Output amplitude balance
(|S
31
/S
21
|)
1930.0 ... 1990.0 MHz
Output phase balance
(φ(S
31
)−φ(S
21
)+180˚)
1930.0 ... 1990.0 MHz
Attenuation
0.0
1510.0
1830.0
1850.0
1890.0
2010.0
2070.0
2400.0
2500.0
3860.0
3980.0
5790.0
...
...
...
...
...
...
...
...
...
...
...
...
1510.0
1830.0
1850.0
1890.0
1910.0
2070.0
2400.0
2500.0
3860.0
3980.0
5790.0
6000.0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
α
–1.2
-0.6/0.5
1.2
dB
–10
-1/+4
10
˚
40
30
26
23
12
11.5
27
35
28
40
28
35
46
37
32
28
18
12.5
29
42
33
49
42
45
—
—
—
—
—
—
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Please read
cautions and warnings and
important notes
at the end of this document.
3
Oct 21, 2005