B32921C/D ... B32926C/D
X2 / 305 V AC
Technical data
Max. operating temperature T
op,max
Dissipation factor tan
δ
(in 10
-3
)
at 20
°C
(upper limit values)
Insulation resistance R
ins
or time constant
τ
= C
R
R
ins
at 20
°C,
rel. humidity
≤
65%
(minimum as-delivered values)
DC test voltage
Passive flammability category
to IEC 40 (CO) 752
+110
°C
C
R
≤0.1 µF
0.1µF<C
R
≤2.2 µF
C
R
>2.2
µF
at
1 kHz
100 kHz
1.0
5.0
C
R
>0.33
µF
1.0
2.0
C
R
≤0.33 µF
100 000 MΩ 30 000 s
2121 V, 2 s
B
Maximum continuous DC voltage V
DC
630 V
Maximum continuous AC voltage V
AC
310 V (50/60 Hz)
Rated AC voltage (IEC 60384-14)
Operating AC voltage V
op
at high
temperature
Damp heat test
Limit values after damp heat test
305 V (50/60 Hz)
T
A
≤
110
°C
T
A
≤
110
°C
V
op
= V
AC
V
op
= 1.25
(continuously)
(1000 h)
V
AC
56 days / 40
°C
/ 93% relative humidity
Capacitance change
∆C/C
≤
5%
Dissipation factor change
∆
tan
δ ≤
0.5 10
-3
(at 1 kHz)
Insulation resistance R
ins
≤
1.0 10
-3
(at 10 kHz)
or time constant
τ
= C
R
R
ins
≥
50% of minimum
as-delivered values
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 6 of 18