B32921C/D ... B32926C/D
X2 / 305 V AC
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k
0
values
Lead spacing
dV/dt in V/µs
k
0
in V
2
/µs
10 mm
475
408500
15 mm
340
292400
22.5 mm
170
146200
27.5 mm
120
103200
37.5 mm
80
68800