Absolute Maximum Ratings (Notes 1, 2)  
Recommended Operating Conditions  
Power Supply Voltage VDD  
Voltage to Any pin  
-5.5V to +5.5V  
Min.  
Max.  
Units  
-0.3 to VDD +0.3V  
300mW  
Power Supply Voltage (VDD  
)
4.0  
5.2  
V
Maximum Power Dissipation  
Storage Temperature Range (TS)  
Lead Temperature solder, 4 sec. (TL)  
-40°C to +85°C  
+260°C  
Operating Temperature (TA)  
Humidity  
-40°  
+5  
+85°  
+95  
C
%
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Recommended operating conditions indic-  
ate conditions for which the device is intended to be functional, but do not guarantee specific performance limits. For guaranteed specifica-  
tions and test conditions, see Electrical Characteristics.  
Note 2: This device is a highly sensitive CMOS ac current amplifier with an ESD rating of JEDEC HBM class 0 (<250V). Handling and as -  
sembly of this device should only be done at ESD protected workstations.  
Electrical Characteristics  
VDD = 5.0 V, -40°C < TA < +85°C  
Symbol  
Parameter  
Conditions/Comments  
Values  
Typ.  
Units  
Min.  
Max.  
VPP  
Ripple on Supply Voltage  
epc135 Sinusoidal 100kHz, refer to other parameters  
epc138  
40  
mVpp  
epc137  
22  
epc136 Sinusoidal 800kHz, refer to other parameters  
epc139  
110  
epc134  
45  
IDD  
Power Supply Current  
All slow no photo diode current  
All fast  
0.45  
0.75  
0.50  
0.80  
mA  
V
VPD  
Reversed Photodiode Voltage  
relative to VDD  
VDD-  
1.55  
IPD  
Input Pulse Threshold  
(Sensitivity)  
epc137 Photodiode current pulse to generate an output pulse  
40  
80  
nA  
nA  
epc135  
epc138  
60  
100  
epc134  
200  
600  
400  
800  
600  
nA  
nA  
epc136  
epc139  
1000  
IPDres Input Pulse Threshold Re-  
serve  
epc134 - Input pulse current relative to IPD to trigger the light re-  
epc137 serve output  
150  
%
IPDmax Input Pulse Current  
If input current is above this level, recovery time tREC is  
undefined (refer to section 'Other Parameters')  
100  
μA  
IPDDC DC Light Current Range  
CPD Photodiode Capacitance  
refer to section 'Application Information, Ambient Light'  
0.0  
15  
3.0  
50  
mA  
pF  
epc135 refer to section 'Application Information, Photodiode  
epc137 Capacitance'  
epc138  
epc134  
epc136  
epc139  
30  
40  
IOUT Output Current (sink)  
When a light pulse above the threshold is detected  
-6.0  
3.0  
-8.0  
3.5  
-10.0  
4.0  
mA  
V
VPOR Power-up Threshold Voltage  
The voltage at VDD when the device starts up and the  
startup time is running.  
VIPOR Hysteresis  
on Power-up Threshold Voltage  
VDD slew rate >100V/ms  
0.5  
0.75  
1.0  
1.5  
1.5  
V
tINIT  
Power-up Startup Time  
ms  
ms  
tOFF Power-down Time  
© 2011 ESPROS Photonics Corporation  