EPC120-QFN16 参数 Datasheet PDF下载

EPC120-QFN16图片预览
型号: EPC120-QFN16
PDF下载: 下载PDF文件 查看货源
内容描述: 完全集成的隔光芯片,带有2线总线接口 [Fully integrated Light-Barrier Chips with 2-Wire Bus Interface]
分类和应用:
文件页数/大小: 27 页 / 550 K
品牌: EPC [ ESPROS PHOTONICS CORP ]
 浏览型号EPC120-QFN16的Datasheet PDF文件第16页浏览型号EPC120-QFN16的Datasheet PDF文件第17页浏览型号EPC120-QFN16的Datasheet PDF文件第18页浏览型号EPC120-QFN16的Datasheet PDF文件第19页浏览型号EPC120-QFN16的Datasheet PDF文件第21页浏览型号EPC120-QFN16的Datasheet PDF文件第22页浏览型号EPC120-QFN16的Datasheet PDF文件第23页浏览型号EPC120-QFN16的Datasheet PDF文件第24页  
epc120  
Data Bits  
N
Function  
Indicates, if new data is available  
N
0
1
Values  
no new data available  
new data available  
D0 … D3  
D4  
Timestamp  
Status of receiver threshold “normal”  
D4  
Values  
0
Receiver threshold set by SENSN not reached  
Receiver threshold set by SENSN exceeded  
1
D5  
Status of receiver threshold “high” (light reserve)  
D4  
Values  
0
Receiver threshold set by SENSH not reached  
Receiver threshold set by SENSH exceeded  
1
D5 … D10  
D11 … D20  
E0 … E3  
empty, not used  
Device address  
Error codes, refer to Chapter Error Codes  
Table 8: Result of a SCAN command  
Command NOP  
The command NOP can be used to fetch the last received data without sending a new command. With this command it is possible to monitor  
the 2-wire interface by a second interface device in a redundant system.  
Command TEST  
The command TEST issues an internal test pulse or a DC current at the PD input pin on a specific receiver. It simulates basically a received  
light pulse or DC sunlight influence to check the proper functionality of the receiver(s) without using an emitter. This mode is initialized by the  
command TEST and is left after a complete SCAN sequence.  
Code  
C0 … C2  
Extension  
R0 … R4  
Amplitude  
D0 … D4  
Current Shape  
111  
10000  
1xxxxx  
x1xxxx  
xx1xxx  
xxx1xx  
xxxx1x  
xxxxx1  
25nA  
50nA  
100nA  
100μA  
500μA DC  
2mA DC  
Pulse  
Pulse  
Pulse  
Pulse  
DC  
DC  
Table 9: Self Test  
The applied current is the sum of different current sources: In column “Pulse Amplitude” of Table 9 a “1” means, that the corresponding  
current is added. Example: 110000 generates a pulse of 75nA without DC.  
Command RESET  
The command RESET resets the device and initiates a startup. All devices can be reset simultaneously by using address 0.  
Command ADRA  
ADRA is used during the configuration of a light curtain system to allocate a logical address to the physical position of the the emitter or  
receiver element.  
The command ADRA stores the device address to the volatile memory only (RAM). If the device address has to be stored permanently, the  
command PROG has to be used to copy the previous stored device address from the RAM register into the ROM register. ADRA can only be  
used if there was no previous PROG command to the address register.  
The address 0 is reserved to address all devices together or none and must not be used as an individual address.  
The command ADRA generates no result.  
For details refer to Chapter Address Programming.  
© 2011 ESPROS Photonics Corporation  
Characteristics subject to change without notice  
20  
Datasheet epc12x - V2.1  
www.espros.ch  
 