欢迎访问ic37.com |
会员登录 免费注册
发布采购

EN25D16-100HI 参数 Datasheet PDF下载

EN25D16-100HI图片预览
型号: EN25D16-100HI
PDF下载: 下载PDF文件 查看货源
内容描述: 16兆位串行闪存 [16 Megabit Serial Flash Memory]
分类和应用: 闪存
文件页数/大小: 37 页 / 483 K
品牌: EON [ EON SILICON SOLUTION INC. ]
 浏览型号EN25D16-100HI的Datasheet PDF文件第6页浏览型号EN25D16-100HI的Datasheet PDF文件第7页浏览型号EN25D16-100HI的Datasheet PDF文件第8页浏览型号EN25D16-100HI的Datasheet PDF文件第9页浏览型号EN25D16-100HI的Datasheet PDF文件第11页浏览型号EN25D16-100HI的Datasheet PDF文件第12页浏览型号EN25D16-100HI的Datasheet PDF文件第13页浏览型号EN25D16-100HI的Datasheet PDF文件第14页  
EN25D16  
INSTRUCTIONS  
All instructions, addresses and data are shifted in and out of the device, most significant bit first.  
Serial Data Input (DI) is sampled on the first rising edge of Serial Clock (CLK) after Chip Select (CS#)  
is driven Low. Then, the one-byte instruction code must be shifted in to the device, most significant  
bit first, on Serial Data Input (DI), each bit being latched on the rising edges of Serial Clock (CLK).  
The instruction set is listed in Table 4. Every instruction sequence starts with a one-byte instruction  
code. Depending on the instruction, this might be followed by address bytes, or by data bytes, or by  
both or none. Chip Select (CS#) must be driven High after the last bit of the instruction sequence  
has been shifted in. In the case of a Read Data Bytes (READ), Read Data Bytes at Higher Speed  
(Fast_Read), Read Status Register (RDSR) or Release from Deep Power-down, and Read Device  
ID (RDI) instruction, the shifted-in instruction sequence is followed by a data-out sequence. Chip  
Select (CS#) can be driven High after any bit of the data-out sequence is being shifted out.  
In the case of a Page Program (PP), Sector Erase (SE), Block Erase (BE), Chip Erase (CE), Write  
Status Register (WRSR), Write Enable (WREN), Write Disable (WRDI) or Deep Power-down (DP)  
instruction, Chip Select (CS#) must be driven High exactly at a byte boundary, otherwise the  
instruction is rejected, and is not executed. That is, Chip Select (CS#) must driven High when the  
number of clock pulses after Chip Select (CS#) being driven Low is an exact multiple of eight. For  
Page Program, if at any time the input byte is not a full byte, nothing will happen and WEL will not be  
reset.  
In the case of multi-byte commands of Page Program (PP), and Release from Deep Power  
Down (RES ) minimum number of bytes specified has to be given, without which, the  
command will be ignored.  
In the case of Page Program, if the number of byte after the command is less than 4 (at least  
1 data byte), it will be ignored too. In the case of SE and BE, exact 24-bit address is a must,  
any less or more will cause the command to be ignored.  
All attempts to access the memory array during a Write Status Register cycle, Program cycle or  
Erase cycle are ignored, and the internal Write Status Register cycle, Program cycle or Erase cycle  
continues unaffected.  
Table 4. Instruction Set  
Instruction Name  
Byte 1  
Code  
Byte 2  
Byte 3  
Byte 4  
Byte 5  
Byte 6  
n-Bytes  
Write Enable  
06h  
04h  
Write Disable / Exit  
OTP mode  
Read Status  
Register  
(1)  
(2)  
05h  
(S7-S0)  
S7-S0  
continuous  
Write Status  
Register  
01h  
03h  
0Bh  
A23-A16  
A23-A16  
A15-A8  
A15-A8  
A7-A0  
A7-A0  
(D7-D0)  
dummy  
(Next byte)  
(D7-D0)  
Read Data  
continuous  
(Next Byte)  
continuous  
Fast Read  
DI =  
(D6, D4, D2, D0)  
DO =  
(one byte  
per 4 clocks,  
continuous)  
Dual Output Fast  
Read  
3Bh  
A23-A16  
A15-A8  
A7-A0  
dummy  
D7-D0  
(D7, D5, D3, D1)  
A23-A16  
A23-A16  
A23-A16  
A15-A8  
A15-A8  
A15-A8  
A7-A0  
A7-A0  
A7-A0  
Next byte  
continuous  
Page Program  
Sector Erase  
Block Erase  
02h  
20h  
D8h/ 52h  
C7h/ 60h  
B9h  
Chip Erase  
Deep Power-down  
This Data Sheet may be revised by subsequent versions  
or modifications due to changes in technical specifications.  
©2004 Eon Silicon Solution, Inc., www.essi.com.tw  
10  
Rev. B, Issue Date: 2008/06/23  
 复制成功!