EM4205-EM4305  
EEPROM Delivery State  
Forward Link Communication  
(Communication from the Reader to the Tag)  
Default configuration is the following:  
First two words (word 0 and 1) are programmed with:  
As already mentioned, the commands are sent from the  
reader to the tag by initiating a command while the  
EM4205/4305 is in default read mode. The  
communication is done by using 100% modulation index  
of reader field (also called field stops or OOK) with a bit  
timing of 32 periods of the RF field. The forward link  
Chip Type  
Resonant capacitor version  
Customer Code  
Unique Identification Number (UID).  
communication  
protocol  
is  
identical  
to  
the  
All the other user free memory words are set to 0.  
EM4569/EM4469.  
The chip is initialized to Bi-phase data encoding, RF/32  
clock data rate. Its LWR value is set to 8.  
When the EM4205/4305 is in Default read mode, the logic  
permanently observes the Data Extractor output (see also  
Timing Characteristics and Block Diagram). The detection  
of field stop initializes the Command mode.  
Default Read  
After the supply voltage crosses the POR threshold, the  
circuit enters Power-up Initialization in which it reads the  
configuration word and then transitions to Default Read  
mode according to configuration just read.  
At reception of the first field stop, the IC stops immediately  
the default read and expects to receive a bit "0" to enter in  
the command processing mode. The transceiver and the  
chip are now synchronized and further data is sent. In the  
case where the first field stop is not followed by bit “0”, the  
IC returns in Default read mode.  
In Default Read mode, the EM4205/4305 sends  
continuously its memory data starting from Word 5 and  
finishing with the last word according to the configuration  
word settings. After sending the last bit of the last word,  
readout continues without interruption with the first bit of  
Word 5.  
The bit timing is composed of two states called MOD_ON  
and MOD_OFF (see figure 10). During the first 16  
periods, the modulator is turned OFF (MOD_OFF)  
allowing the recharge of the internal supply capacitor.  
Then, the chip modulator is turned ON for the next 16  
periods (MOD_ON). To receive a logic "0" bit, the IC has  
to detect a field stop before the end of MOD_ON state. If  
this field stop is not detected, a logic "1" is received.  
8
www.emmicroelectronic.com  
Copyright 2013, EM Microelectronic-Marin SA  
4205-4305-DS-01.doc, Version 4.0, 22-Oct-13  