EM4205-EM4305  
Timing Characteristics  
VDD = 2.0 V, VSS = 0 V, fCOIL1 = 125kHz square wave, VCOIL1 = 4VPP, TOP = 25°C,  
Data rate fRF/32, Bi-phase unless otherwise specified  
Parameter  
Symbol  
tMONO  
tWEE  
tPR  
Conditions  
Min.  
20  
Typ.  
40  
9.34  
12.16  
1.48  
3.3  
Max.  
60  
Unit  
s  
ms  
ms  
ms  
ms  
s  
Data Extractor timeout  
EEPROM programming time  
Protection words update time  
Power check time  
Power-up initialization  
Processing Pause  
tPC  
tPU  
tPP  
586  
Table 4  
Data Extractor timeout (tMONO  
)
COIL1-COIL2  
CLOCK  
TIMEOUT  
tMONO  
FIELD STOP  
Figure 2  
Transceiver field is amplitude modulated (field stops) to transmit data to the EM4205/4305. Data extractor detects absence  
of signal on coil terminals for period longer then TMONO. Please note that the field has to be stopped for a much longer  
period of time than TMONO. In figure above magnetic field is stopped when modulator switch is OFF. Second signal shows  
internal clock signal, which continues to be extracted up to the point where COIL1-COIL2 signal is lower then 1Vpp. Third  
signal, Timeout, indicates to the chip logic that a magnetic field stop was detected. The field stop detection time is at least  
TMONO after the last extracted clock from the coil voltage. The length of transceiver field stop depends on the Q factor of the  
transponder. First field stop has to be longer (~18 - 20 RF cycles) since it is possible that it happens when chip modulator  
switch is off.  
Power-up initialization (tPU  
)
tPU  
Figure 3  
After the supply voltage crosses the POR threshold, the logic reads configuration word and then enters in default read  
mode. tPU is the time from turning on transmitter field to start of the default read mode.  
3
www.emmicroelectronic.com  
Copyright 2013, EM Microelectronic-Marin SA  
4205-4305-DS-01.doc, Version 4.0, 22-Oct-13  