NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
40-50 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
VOLTAGE
TOTAL
RIPPLE (3)
MODEL NUMBER (11,12)
MAX (1)
4 A
PEAK (2)
5 A
FAN (1)
4.5 A
3 A
REGULATION
+3.3 V (IA)
+12 V (IB)
–12 V (IC)
+5 V (IA)
+12 V (IB)
–12 V (IC)
+5 V (IA)
+15 V (IB)
–15 V (IC)
+12 V (IA)
-12 V (IB)
+5 V (IA)
+12 V (IB)
3.3 V (IA)
5 V
50 mV
120 mV
120 mV
50 mV
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
2.0%
5.0%
5.0%
2.0%
5.0%
2.0%
5.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
NLP40-76T366J (5)
2 A
3 A
0.2 A
4 A
1 A
0.5 A
4.5 A
3 A
5 A
NLP40-7608J (5)
NLP40-7610J (5)
2 A
3 A
120 mV
120 mV
50 mV
0.2 A
4 A
1 A
0.5 A
4.5 A
2 A
5 A
1.6 A
0.2 A
1.8 A
1.8 A
4 A
2 A
150 mV
150 mV
120 mV
120 mV
50 mV
1 A
0.5 A
2.1 A
2.1 A
4.5 A
3 A
2.2 A
2.2 A
5 A
NLP40-7627J (5)
NLP40-7629J (5)
2 A
3 A
120 mV
50 mV
8 A
10 A
10 A
4.5 A
3.6 A
2.5 A
1.1 A
9 A
NLP40-76S3J
NLP40-7605J
NLP40-7612J
NLP40-7615J
NLP40-7624J
NLP40-7617J
8 A
9 A
50 mV
12 V
3.3 A
2.6 A
1.6 A
0.8 A
4 A
120 mV
150 mV
240 mV
300 mV
15 V
3.3 A
2 A
24 V
48 V
1 A
Notes
DERATING CURVE
Output Power (Watts)
1
2
3
Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
50W
40W
20 CFM FORCED AIR COOLING
4
5
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
25W
20W
NATURAL
CONVECTION
COOLING
0.25 ≤ I / I ≤ 5, for I > 0.3 A
A
B
B
0.50 ≤ I / I ≤ 5, for I < 0.3 A
A
B
B
For maximum output current I(C) on triple output models, i.e. for
= IMax., I min. ≥ 0.5 A and I ≥ I .
I
C
A
A
B
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ I / I ≤ 2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ I / I ≤ 4.
A
B
A
B
6
7
8
9
For optimum reliability, no part of the heatsink should exceed 120 °C, and
no semiconductor case temperature should exceed 130 °C.
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
When the input voltage is <90 Vac the operating range is 0 °C to +40 °C.
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
10 For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
File Name: nlp40.pdf Rev (03): 08 Nov 2005