Twinax/Triax Connectors /
Specifications
3
MIL-STD-1553B Data Bus General Specifications Guide (cont’d)
Characteristic Requirements
Corona Level (min.)
Rise Time Degradation (max.)
Permeability of Nonmagnetic Material
Hermetic Seal
(Where Applicable)
Connector Durability
Temperature Range
Force to Engage and Disengage
Longitudinal (max.)
Torque (max.)
Center Contact Retention
Axial Force (min.)
Plug
Jack
Coupling Proof Torque
(Threaded types only)
Coupling Mechanism Retention Force
(min.)
Cable Retention Force (min.)
70 Series
TRB/TRT
200 VRMS
@ 70,000 ft.
400 rs
80 Series
TRC/TRN
375 VRMS
@ 70,000 ft.
N/A
150 Series
TRS/TTM
125 VRMS
@ 70,000 ft.
800 ps
450 Series
TCS
250 VAC
@ 50,000 ft.
800 ps
<2.0 mu except hermetic versions
<1 x 10-8 cc/sec
N/A
<1 x 10-6 cc/sec
N/A
500 cycles minimum @ 12 cycles per minute max.
-65° to +165°C
4 pounds
2.5 inch-pounds
-65° to +165°C
5 pounds
4 inch-pounds
-65° to +200°C
4 pounds
2.5 inch-pounds
-65° to 125°C
3 pounds
2.5 inch-pounds
6 pounds
6 pounds
15 inch-pounds
100 pounds
40 pounds
.200-.325 inch
cable OD
6 pounds
6 pounds
15 inch-pounds
100 pounds
65 pounds
.242-.419 inch
cable OD
4 pounds
2 pounds
10 inch-pounds
70 pounds
40 pounds
.120-.215 inch
cable OD
6 pounds
6 pounds
N/A
100 pounds
40 pounds
.120-.180 inch
cable OD
Salt Spray (corrosion)
Moisture Resistance (10 cycles)
Thermal Shock (5 cycles)
(No physical damage/Pass DWV)
Specified Shock (sawtooth waveform,
within peak - 50g’s, duration -11ms)
Vibration, High-frequency (36 cycles)
(15g peak, 10-2000 Hz-10Hz in 20 minutes)
48 hrs minimum exposure (Standard nickel plating)
500 hrs minimum available (Call customer service for plating types). Standard for 450 Series.
TWINAX/TRIAX CONNECTORS
Total 240 hour minimum exposure
Total 5 hours 50 minutes min -65°C to +85°C
-65°C to +125°C
No discontinuity allowed. Velocity-change of shock pulse 10% of ideal value
Total 12 hour minimum. No physical damage or loosening of parts.
No discontinuity allowed.
* Specifications are minimum unless otherwise stated. Trompeter connectors are designed to exceed all minimum specifications.