EM65101
128COM/160SEG 16 Gray Scale Level LCD Driver
7.19 Register Setting Examples
7.19.1 Initialization
Power ON (VDD,VEE-VSS)
Power will stable
RESET
WAIT
Setting Operational Functions
* Electrical volume set
* Bias Ratio set
Setting Operational Functions
* Setting power control
(DCON= "1", AMPON= "1")
End of initialization
Figure 7-22 Initialization Register Setting Sequential Flow
Product Specification (V0.4) 08.15.2005
• 39
(This specification is subject to change without further notice)