EBE41AE4ACFA
DC Characteristics 1 (TC = 0°C to +85°C, VDD = 1.8V ± 0.1V, VSS = 0V)
Parameter
Symbol Grade
max
Unit
Test condition
one bank; tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Operating current
(ACT-PRE)
-8E
IDD0
3772
3457
mA
-6E
one bank; IOUT = 0mA; BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRC = tRC (IDD),
Operating current
(ACT-READ-PRE)
-8E
IDD1
4189
3842
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
mA
mA
-6E
Data pattern is same as IDD4W
all banks idle;
tCK = tCK (IDD);
CKE is L;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge power-down
standby current
-8E
IDD2P
940
895
-6E
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge quiet standby
current
-8E
IDD2Q
1840
1615
mA
mA
-6E
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-8E
IDD2N
2020
1795
Idle standby current
-6E
all banks open;
Fast PDN Exit
-8E
IDD3P-F
-6E
1840
1795
mA
mA
tCK = tCK (IDD);
MRS(12) = 0
CKE is L;
Active power-down
standby current
Other control and address
bus inputs are STABLE;
Data bus inputs are
FLOATING
-8E
IDD3P-S
-6E
1300
1255
Slow PDN Exit
MRS(12) = 1
all banks open;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-8E
IDD3N
3862
3457
Active standby current
mA
mA
-6E
all banks open, continuous burst reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
Operating current
-8E
IDD4R
5269
4652
-6E
(Burst read operating)
all banks open, continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Operating current
-8E
IDD4W
5269
4652
mA
-6E
(Burst write operating)
Data Sheet E1078E40 (Ver. 4.0)
12