EBE11ED8AJWA
DC Characteristics 1 (TC = 0°C to +85°C, VDD = 1.8V ± 0.1V, VSS = 0V)
Parameter
Symbol
IDD0
Grade
max.
Unit
mA
Test condition
Operating current
(ACT-PRE)
(Another rank is in IDD2P)
-8E, -8G
-6E
585
540
one bank; tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Operating current
(ACT-PRE)
(Another rank is in IDD3N)
-8E, -8G
-6E
855
765
IDD0
IDD1
mA
mA
one bank; IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
Operating current
-8E, -8G
-6E
675
630
(ACT-READ-PRE) (Another
rank is in IDD2P)
tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
Operating current
-8E, -8G
-6E
945
855
IDD1
mA
mA
(ACT-READ-PRE) (Another
rank is in IDD3N)
all banks idle;
tCK = tCK (IDD);
CKE is L;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge power-down
standby current
IDD2P
180
270
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge quiet standby
current
IDD2Q
IDD2N
mA
mA
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are
SWITCHING;
Idle standby current
360
Data bus inputs are SWITCHING
all banks open;
tCK = tCK (IDD);
CKE is L;
Fast PDN Exit
MRS(12) = 0
IDD3P-F
IDD3P-S
270
216
mA
mA
Active power-down standby
current
Other control and address
bus inputs are STABLE;
Data bus inputs are
MRS(12) = 1
FLOATING
Slow PDN Exit
all banks open;
tCK = tCK (IDD), tRAS = tRAS max.(IDD),
tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are
SWITCHING;
-8E, -8G
-6E
720
630
Active standby current
IDD3N
mA
Data bus inputs are SWITCHING
Operating current
all banks open, continuous burst reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP
(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
-8E, -8G
-6E
1215
1080
IDD4R
IDD4R
IDD4W
IDD4W
mA
mA
mA
mA
(Burst read operating)
(Another rank is in IDD2P)
Operating current
-8E, -8G
-6E
1485
1305
(Burst read operating)
(Another rank is in IDD3N)
Operating current
all banks open, continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP
(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-8E, -8G
-6E
1170
1035
(Burst write operating)
(Another rank is in IDD2P)
Operating current
-8E, -8G
-6E
1440
1260
(Burst write operating)
(Another rank is in IDD3N)
Data Sheet E1054E30 (Ver. 3.0)