欢迎访问ic37.com |
会员登录 免费注册
发布采购

EBE11UD8ABFA-4A-E 参数 Datasheet PDF下载

EBE11UD8ABFA-4A-E图片预览
型号: EBE11UD8ABFA-4A-E
PDF下载: 下载PDF文件 查看货源
内容描述: 1GB无缓冲DDR2 SDRAM DIMM ( 128M字× 64位, 2级) [1GB Unbuffered DDR2 SDRAM DIMM (128M words x 64 bits, 2 Ranks)]
分类和应用: 动态存储器双倍数据速率
文件页数/大小: 22 页 / 172 K
品牌: ELPIDA [ ELPIDA MEMORY ]
 浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第7页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第8页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第9页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第10页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第12页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第13页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第14页浏览型号EBE11UD8ABFA-4A-E的Datasheet PDF文件第15页  
EBE11UD8ABFA  
DC Characteristics 1 (TC = 0 to +85°C, VDD = 1.8V ± 0.1V, VSS = 0V)  
Parameter  
Symbol Grade  
max.  
Unit  
mA  
Test condition  
Operating current  
(ACT-PRE)  
(Another rank is in IDD2P)  
-5C  
IDD0  
960  
824  
one bank; tCK = tCK (IDD), tRC = tRC (IDD),  
tRAS = tRAS min.(IDD);  
CKE is H, /CS is H between valid commands;  
Address bus inputs are SWITCHING;  
Data bus inputs are SWITCHING  
-4A  
Operating current  
(ACT-PRE)  
(Another rank is in IDD3N)  
-5C  
IDD0  
1400  
1240  
mA  
mA  
-4A  
one bank; IOUT = 0mA;  
BL = 4, CL = CL(IDD), AL = 0;  
Operating current  
-5C  
IDD1  
1080  
944  
(ACT-READ-PRE)  
(Another rank is in IDD2P)  
-4A  
tCK = tCK (IDD), tRC = tRC (IDD),  
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);  
CKE is H, /CS is H between valid commands;  
Address bus inputs are SWITCHING;  
Data pattern is same as IDD4W  
Operating current  
-5C  
IDD1  
1520  
1360  
mA  
mA  
(ACT-READ-PRE)  
(Another rank is in IDD3N)  
-4A  
all banks idle;  
tCK = tCK (IDD);  
CKE is L;  
Other control and address bus inputs are STABLE;  
Data bus inputs are FLOATING  
-5C  
-4A  
IDD2P  
160  
128  
400  
320  
480  
400  
Precharge power-down  
standby current  
-5C  
-4A  
all banks idle;  
tCK = tCK (IDD);  
CKE is H, /CS is H;  
Other control and address bus inputs are STABLE;  
Data bus inputs are FLOATING  
-5C  
IDD2Q  
Precharge quiet standby  
current  
mA  
mA  
-4A  
all banks idle;  
tCK = tCK (IDD);  
CKE is H, /CS is H;  
Other control and address bus inputs are SWITCHING;  
Data bus inputs are SWITCHING  
-5C  
IDD2N  
Idle standby current  
-4A  
all banks open;  
Fast PDN Exit  
tCK = tCK (IDD);  
MRS(12) = 0  
CKE is L;  
-5C  
IDD3P-F  
-4A  
640  
560  
mA  
mA  
Active power-down  
standby current  
Other control and address bus  
inputs are STABLE;  
-5C  
400  
320  
Slow PDN Exit  
MRS(12) = 1  
IDD3P-S  
Data bus inputs are FLOATING  
-4A  
all banks open;  
-5C  
IDD3N  
1040  
960  
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);  
CKE is H, /CS is H between valid commands;  
Other control and address bus inputs are SWITCHING;  
Data bus inputs are SWITCHING  
Active standby current  
mA  
-4A  
Operating current  
all banks open, continuous burst reads, IOUT = 0mA;  
BL = 4, CL = CL(IDD), AL = 0;  
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);  
CKE is H, /CS is H between valid commands;  
Address bus inputs are SWITCHING;  
-5C  
IDD4R  
1600  
1264  
mA  
mA  
mA  
mA  
(Burst read operating)  
(Another rank is in IDD2P)  
-4A  
Operating current  
(Burst read operating)  
(Another rank is in IDD3N)  
-5C  
IDD4R  
2040  
1680  
-4A  
Data pattern is same as IDD4W  
Operating current  
(Burst write operating)  
(Another rank is in IDD2P)  
all banks open, continuous burst writes;  
BL = 4, CL = CL(IDD), AL = 0;  
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);  
CKE is H, /CS is H between valid commands;  
Address bus inputs are SWITCHING;  
Data bus inputs are SWITCHING  
-5C  
IDD4W  
1600  
1264  
-4A  
Operating current  
-5C  
IDD4W  
2040  
1680  
(Burst write operating)  
(Another rank is in IDD3N)  
-4A  
tCK = tCK (IDD);  
Auto-refresh current  
(Another rank is in IDD2P)  
-5C  
IDD5  
2080  
1904  
mA  
mA  
Refresh command at every tRFC (IDD) interval;  
CKE is H, /CS is H between valid commands;  
Other control and address bus inputs are SWITCHING;  
Data bus inputs are SWITCHING  
-4A  
Auto-refresh current  
(Another rank is in IDD3N)  
-5C  
IDD5  
2520  
2320  
-4A  
Data Sheet E0365E50 (Ver. 5.0)  
11  
 复制成功!