EBE10UE8AEFA
DC Characteristics 1 (TC = 0°C to +85°C, VDD = 1.8V ± 0.1V, VSS = 0V)
Parameter
Symbol Grade
max.
Unit
mA
Test condition
one bank; tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Operating current
(ACT-PRE)
-8G
IDD0
680
640
-6E
one bank; IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRC = tRC (IDD),
tRAS = tRAS min.(IDD); tRCD = tRCD (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data pattern is same as IDD4W
Operating current
(ACT-READ-PRE)
-8G
IDD1
800
760
mA
-6E
all banks idle;
tCK = tCK (IDD);
CKE is L;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge power-down
standby current
IDD2P
80
mA
mA
mA
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are STABLE;
Data bus inputs are FLOATING
Precharge quiet standby
current
-8G
IDD2Q
280
240
-6E
all banks idle;
tCK = tCK (IDD);
CKE is H, /CS is H;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-8G
IDD2N
320
280
Idle standby current
-6E
all banks open;
Fast PDN Exit
tCK = tCK (IDD);
MRS(12) = 0
CKE is L;
IDD3P-F
IDD3P-S
280
160
mA
mA
Active power-down
standby current
Other control and address bus
inputs are STABLE;
Slow PDN Exit
MRS(12) = 1
Data bus inputs are FLOATING
all banks open;
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
-8G
IDD3N
720
640
Active standby current
mA
mA
-6E
all banks open, continuous burst reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = 0;
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Operating current
-8G
IDD4R
1280
1120
-6E
(Burst read operating)
Data pattern is same as IDD4W
all banks open, continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
Operating current
-8G
IDD4W
1280
1120
tCK = tCK (IDD), tRAS = tRAS max.(IDD), tRP = tRP (IDD);
CKE is H, /CS is H between valid commands;
Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
mA
-6E
(Burst write operating)
Data Sheet E1295E40 (Ver. 4.0)
12