ELM329  
AT Commands  
Several parameters within the ELM329 can be  
it was successfully completed.  
adjusted in order to modify its behaviour. These do not  
normally have to be changed before attempting to talk  
to the vehicle, but occasionally the user may wish to  
customize these settings – for example by turning the  
character echo off, adjusting a timeout value, or  
changing the header (ID) bytes. In order to do this,  
internal ‘AT’ commands must be used.  
Those familiar with PC modems will immediately  
recognize AT commands as a standard way in which  
modems are internally configured. The ELM329 uses  
essentially the same method, always watching the  
data sent by the PC, looking for messages that begin  
with the character ‘A’ followed by the character ‘T’. If  
found, the next characters will be interpreted as an  
internal configuration or ‘AT’ command, and will be  
executed upon receipt of a terminating carriage return  
character. If the command is just a setting change, the  
ELM329 will reply with the characters ‘OK’, to say that  
Some of the commands require that numbers be  
provided as arguments, in order to set the internal  
values. These will always be hexadecimal numbers  
which must generally be provided in pairs. The  
hexadecimal conversion chart in the OBD Commands  
section (page 26) may be helpful if you wish to  
interpret the values. Also, one should be aware that for  
the on/off types of commands, the second character is  
the number 1 or the number 0, the universal terms for  
on and off.  
The remainder of this page, and the next page  
following provide a summary of all of the commands  
that the current version of the ELM329 recognizes. A  
more complete description of each command begins  
on page 11.  
AT Command Summary  
ELM329 Options  
Programmable Parameters  
<CR>  
BRD hh  
BRT hh  
D
repeat the last command  
try Baud Rate Divisor hh  
set Baud Rate Timeout  
set all to Defaults  
PP xx OFF  
PP FF OFF  
PP xx ON  
PP FF ON  
disable Prog Parameter xx  
all Prog Parameters disabled  
enable Prog Parameter xx  
all Prog Parameters enabled  
E0, E1  
I
Echo off, or on*  
PP xx SV yy for PP xx, Set the Value to yy  
print the version ID  
PPS  
print a PP Summary  
L0, L1  
LP  
Linefeeds off, or on  
Voltage Readings  
CV dddd  
CV 0000  
go to low power mode  
Memory off, or on  
Calibrate the Voltage to dd.dd volts  
restore CV value to factory setting  
Read the input Voltage  
M0, M1  
RD  
Read the stored Data  
Save Data byte hh  
RV  
SD hh  
WS  
Warm Start (quick software reset)  
reset all  
Other  
C0, C1  
IGN  
Z
Control Output off*, or on  
read the IgnMon input level  
read INput 1 level  
@1  
display the device description  
display the device identifier  
@2  
IN1  
@3 cccccccccccc store the @2 identifier  
IN2  
read INput 2 level  
Note: Settings shown with an asterisk (*)  
are the default values  
ELM329DSB  
Elm Electronics – Circuits for the Hobbyist  
9 of 76  
www.elmelectronics.com  
 
 复制成功!