ELM329  
Error Messages and Alerts (continued)  
LV RESET  
STOPPED  
The ELM329 continually monitors the 5V supply to  
ensure that it is within acceptable limits. If the voltage  
should go below the low limit, a ‘brownout reset’ circuit  
is activated, and the IC stops all activity. When the  
voltage returns to normal, the ELM329 performs a full  
reset, and then prints LV RESET. Note that this type of  
reset is exactly the same as an AT Z or MCLR reset  
(but it prints LV RESET instead of ELM329 v2.0).  
This low voltage protection is not only necessary  
for the ELM329 to operate properly, but it also offers  
protection for the CAN transceiver ICs too. Most  
transceiver chips require a minimum operating voltage  
of 4.5V, while some require a minimum of 4.75V.  
If any OBD operation is interrupted by a received  
RS232 character, or by a low level on the RTS pin, the  
ELM329 will print the word STOPPED. If you should  
see this response, then something that you have done  
has interrupted the ELM329. Note that short duration  
pulses on pin 15 may cause the STOPPED message  
to be displayed, but may not be of sufficient duration to  
cause a switch to low power operation.  
The message is printed any time that an OBD task  
is interrupted.  
UNABLE TO CONNECT  
The ELM329 has tried all of the available  
protocols, and could not detect a compatible one. This  
could be because your vehicle uses an unsupported  
protocol, or could be as simple as forgetting to turn the  
ignition key on. Check all of your connections, and the  
ignition, then try the command again.  
NO DATA  
The IC waited for the period of time that was set  
by AT ST, and detected no response from the vehicle.  
It may be that the vehicle had no data to offer for that  
particular PID, that the mode requested was not  
supported, that the vehicle was attending to higher  
priority issues, or possibly that the filter was set so that  
the response was ignored, even though one was sent.  
If you are certain that there should have been a  
response, try increasing the ST time (to be sure that  
you have allowed enough time for the ECU to  
respond), or restoring the CAN filter to its default  
setting.  
?
This is the standard response for a misunderstood  
command received on the RS232 input. Usually it is  
due to a typing mistake, but it can also occur if you try  
to do something that is not appropriate for the protocol.  
<RX ERROR  
An error was detected in the received CAN data.  
This most often occurs if monitoring a CAN bus using  
an incorrect baud rate setting, but it may occur if  
monitoring and there are messages found that are not  
being acknowledged, or that contain bit errors. The  
entire message will be displayed as it was received (if  
you have filters set, the received message may not  
agree with the filter setting). Try a different protocol, or  
a different baud rate.  
SEARCHING  
This will be displayed when a message has been  
provided for transmitting, but a protocol is not yet  
considered to be active. When displayed, it means that  
the ELM329 is searching for an appropriate protocol to  
use. Similarly, the message may be displayed if the IC  
is directed to monitor the data bus, and there is no  
protocol active.  
ELM329DSB  
Elm Electronics – Circuits for the Hobbyist  
www.elmelectronics.com  
73 of 76  
 
 复制成功!