ELM327  
AT Commands  
Several parameters within the ELM327 can be  
ELM327 will reply with the characters ‘OK’, to say that  
it was successfully completed.  
adjusted in order to modify its behaviour. These do not  
normally have to be changed before attempting to talk  
to the vehicle, but occasionally the user may wish to  
customize these settings – for example by turning the  
character echo off, adjusting a timeout value, or  
changing the header bytes. In order to do this, internal  
‘AT’ commands must be used.  
Those familiar with PC modems will immediately  
recognize AT commands as a standard way in which  
modems are internally configured. The ELM327 uses  
essentially the same method, always watching the  
data sent by the PC, looking for messages that begin  
with the character ‘A’ followed by the character ‘T’. If  
found, the next characters will be interpreted as an  
internal configuration or ‘AT’ command, and will be  
executed upon receipt of a terminating carriage return  
character. If the command is just a setting change, the  
Some of the following commands allow passing  
numbers as arguments in order to set the internal  
values. These will always be hexadecimal numbers  
which must generally be provided in pairs. The  
hexadecimal conversion chart in the OBD Commands  
section (page 29) may be helpful if you wish to  
interpret the values. Also, one should be aware that for  
the on/off types of commands, the second character is  
the number 1 or the number 0, the universal terms for  
on and off.  
The remainder of this page, and the two pages  
following provide a summary of all of the commands  
that the current version of the ELM327 recognizes. A  
more complete description of each command begins  
on page 11. Note that the settings which are shown  
with an asterisk (*) are the default values.  
AT Command Summary  
General Commands  
Programmable Parameter Commands  
<CR>  
BRD hh  
BRT hh  
D
repeat the last command  
try Baud Rate Divisor hh  
set Baud Rate Timeout  
set all to Defaults  
PP xx OFF disable Prog Parameter xx  
PP FF OFF all Prog Parameters disabled  
PP xx ON enable Prog Parameter xx  
PP FF ON all Prog Parameters enabled  
PP xx SV yy for PP xx, Set the Value to yy  
E0, E1  
FE  
Echo off, or on*  
Forget Events  
PPS  
print a PP Summary  
I
print the version ID  
L0, L1  
LP  
Linefeeds off, or on  
go to Low Power mode  
Memory off, or on  
Voltage Reading Commands  
CV dddd  
CV 0000  
RV  
Calibrate the Voltage to dd.dd volts  
M0, M1  
RD  
restore CV value to factory setting  
Read the input Voltage  
Read the stored Data  
Save Data byte hh  
SD hh  
WS  
Warm Start (quick software reset)  
reset all  
Other  
IGN  
Z
@1  
display the device description  
display the device identifier  
read the IgnMon input level  
@2  
@3 cccccccccccc store the @2 identifier  
ELM327DSI  
Elm Electronics – Circuits for the Hobbyist  
9 of 82  