欢迎访问ic37.com |
会员登录 免费注册
发布采购

5962-9175501MPA 参数 Datasheet PDF下载

5962-9175501MPA图片预览
型号: 5962-9175501MPA
PDF下载: 下载PDF文件 查看货源
内容描述: [Comparator, 1 Func, 5000uV Offset-Max, BIPolar, CDIP8,]
分类和应用: 放大器
文件页数/大小: 11 页 / 64 K
品牌: ELANTEC [ ELANTEC SEMICONDUCTOR ]
 浏览型号5962-9175501MPA的Datasheet PDF文件第3页浏览型号5962-9175501MPA的Datasheet PDF文件第4页浏览型号5962-9175501MPA的Datasheet PDF文件第5页浏览型号5962-9175501MPA的Datasheet PDF文件第6页浏览型号5962-9175501MPA的Datasheet PDF文件第7页浏览型号5962-9175501MPA的Datasheet PDF文件第8页浏览型号5962-9175501MPA的Datasheet PDF文件第10页浏览型号5962-9175501MPA的Datasheet PDF文件第11页  
TABLE II. Electrical test requirements.  
Subgroups  
Test requirements  
Subgroups  
(in accordance with  
(in accordance with  
MIL-STD-883,  
MIL-PRF-38535, table III)  
method 5005, table I)  
Device  
class M  
1
Device  
class Q  
Device  
class V  
Interim electrical  
1
1
parameters (see 4.2)  
Final electrical  
1,2,3,4 1/  
1,2,3,4 1/  
1,2,3,4 1/  
parameters (see 4.2)  
Group A test  
1,2,3,4,5,6,9  
1,2,3,4,5,6,9  
1,2,3,4,5,6,9  
requirements (see 4.4)  
Group C end-point electrical  
parameters (see 4.4)  
Group D end-point electrical  
parameters (see 4.4)  
Group E end-point electrical  
parameters (see 4.4)  
1
1
1
1
1
1
---  
---  
---  
1/ PDA applies to subgroup 1.  
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table II herein.  
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:  
a. Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level  
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the  
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of  
MIL-STD-883.  
b.  
T = +125C, minimum.  
A
c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.  
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,  
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The  
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with  
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the  
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of  
MIL-STD-883.  
SIZE  
STANDARD  
5962-91755  
A
MICROCIRCUIT DRAWING  
DLA LAND AND MARITIME  
REVISION LEVEL  
A
SHEET  
COLUMBUS, OHIO 43218-3990  
9
DSCC FORM 2234  
APR 97