A2D250-AA02-47  
AC axial fan  
straight blades (A series), single-intake  
ebm-papst Mulfingen GmbH & Co. KG  
Bachmühle 2 · D-74673 Mulfingen  
Phone +49 7938 81-0  
Fax +49 7938 81-110  
info1@de.ebmpapst.com  
www.ebmpapst.com  
Limited partnership · Headquarters Mulfingen  
Amtsgericht (court of registration) Stuttgart · HRA 590344  
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen  
Amtsgericht (court of registration) Stuttgart · HRB 590142  
Nominal data  
Type  
A2D250-AA02-47  
M2D068-DF  
Motor  
Phase  
3~  
230  
Δ
3~  
230  
Δ
3~  
400  
Y
3~  
400  
Y
Nominal voltage  
Wiring  
VAC  
Hz  
Frequency  
50  
60  
50  
60  
Method of obtaining data  
Valid for approval/standard  
Speed (rpm)  
fa  
fa  
fa  
fa  
CE  
2650  
110  
0.38  
250  
1
CE  
2950  
160  
0.45  
300  
1.2  
-25  
40  
CE  
2650  
110  
0.22  
250  
1
CE  
2950  
160  
0.26  
300  
1.2  
-25  
40  
min-1  
W
Power consumption  
Current draw  
A
Max. back pressure  
Max. back pressure  
Min. ambient temperature  
Max. ambient temperature  
Pa  
inH2O  
°C  
-25  
70  
-25  
70  
°C  
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment  
Subject to change  
Data according to ErP Directive  
Actual  
Req. 2015  
01 Overall efficiency ηes  
02 Measurement category  
03 Efficiency category  
04 Efficiency grade N  
%
28.1  
28.1  
09 Power consumption Pe  
09 Air flow qv  
kW  
0.13  
1050  
121  
A
m³/h  
Pa  
Static  
40  
09 Pressure increase pfs  
10 Speed (rpm) n  
40  
min-1  
2600  
1.00  
05 Variable speed drive  
No  
11 Specific ratio*  
Data obtained at optimum efficiency level.  
* Specific ratio = 1 + pfs / 100 000 Pa  
LU-69121  
The ErP data is determined using a motor-impeller combination in a standardized measurement setup.  
Item no. 13665-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 1 / 6  
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com