欢迎访问ic37.com |
会员登录 免费注册
发布采购

4114N2H7P 参数 Datasheet PDF下载

4114N2H7P图片预览
型号: 4114N2H7P
PDF下载: 下载PDF文件 查看货源
内容描述: [DC axial fans]
分类和应用:
文件页数/大小: 1 页 / 146 K
品牌: EBMPAPST [ ebm-papst ]
   
Max. 570 m3/h  
DC axial fans  
119 x 38 mm  
Possible special versions:  
(See chapter DC fans - specials)  
- Speed signal  
Material:  
Housing: Die-cast aluminum  
Impeller: GRP1) (PA)  
Direction of air flow: Intake over struts  
Direction of rotation: Clockwise, looking  
towards rotor  
- Go / NoGo alarm  
- Alarm with speed limit  
- External temperature sensor  
- Internal temperature sensor  
- PWM control input (standard)  
- Analog control input  
Connection:  
Via single wires AWG 18, 20 or  
AWG 22, TR 64, speed signal  
and control input AWG 22  
Highly efficient and smoothly  
operating 3-phase fan drive  
Housing with grounding lug for  
screw M4 x 8 (Torx)  
Highlights:  
- Moisture protection  
- Salt spray protection  
Weight:  
425 g  
1) Fiberglass-reinforced plastic  
Series 4100 N  
High Performance  
Nominal data  
Type  
m3/h  
cfm  
VDC  
VDC  
dB(A) Bel(A)  
/
Watts  
rpm-1  
°C  
Hours  
Hours  
4114 N/2 H7P  
4114 N/2 H8P  
500  
570  
294  
336  
24  
24  
16...30  
16...30  
76  
78  
8.5  
8.9  
90  
9 500  
-20...+75  
-20...+75  
57 500 / 25 000  
55 000 / 22 500  
97 500  
92 500  
¿
¡
120  
11 000  
4118 N/2 H7P  
500  
570  
294  
336  
48  
48  
36...60*  
36...60*  
76  
78  
8.5  
8.9  
90  
9 500  
-20...+75  
-20...+75  
57 500 / 25 000  
55 000 / 22 500  
97 500  
92 500  
¿
¡
4118 N/2 H8P  
120  
11 000  
Subject to change  
* 36...72 VDC on request.  
Speed control range from 500 rpm-1 up to maximum nominal speed.  
Standstill at 0% PWM, maximum speed if control cable is interrupted.  
To attain the specified service life, an external capacitor must be wired  
between the plus and minus strands. Please note the wiring suggestion on page 16.  
** Power consumption at free air flow, these values can be significantly higher in the operating point.  
** Power consumption - in operation  
Fan type  
optimum  
operating range (W)  
4114 NH7P  
4114 NH8P  
4118 NH7P  
4118 NH8P  
100  
160  
100  
160  
Air performance measured according to: ISO 5801.  
Installation category A, without contact protection.  
Noise: Total sound power level L A ISO 103002  
W
measured on a hemisphere with a radius of 2 m.  
Sound pressure level L A measured at 1 m distance  
p
from fan axis.  
The values given are applicable only under the specified  
measuring conditions and may differ depending on the  
installation conditions.  
In the event of deviation from the standard configuration,  
the parameters must be checked after installation!  
For detailed information see  
http://www.ebmpapst.com/general conditions  
Finger guards  
from p. 242  