Milli-Cap®
July 8, 2010
Termination Finish and Recommended Attachment Methods
Recommended Attachment Materials:
Termination Finish
Description
•
•
Conductive Epoxy (EPO TEK® H20E, Ablebond® 84-1 LMI, etc.)
Solder (SN62, SN63, etc.)
Code
S
7.5 ± 5µ” Au over 50µ” minimum Ni
•
Recommended Attachment to Soft or Hard Substrate Using Conductive Epoxy:
¾ Recommended Micro Strip Layout:
Gap:
.015” - .020”
(.008” - .010” for P21)
Epoxy Thickness:
.003” - .005”
Ideal Micro Strip Width:
.020” - .025”
(.012” - .015” for P21)
Epoxy Diameter:
.010 - .015”
(.005” - .008” for P21)
Distance from Trace Edge:
.003” - .004”
¾ Attachment Method
1. Place a single drop of conductive epoxy onto each micro-strip as illustrated; the edge of the epoxy shall
be at least .003”- .004” back from the edge of the trace to prevent filling the gap with epoxy.
2. Centering the termination gap of the capacitor within the gap in the micro strip, press with careful, even
pressure onto the micro strip ensuring the terminations make good contact with the epoxy drops.
3. Cure according to the epoxy manufacturer’s preferred schedule
•
Typically 125°C to 150°C Max.
4. After curing, inspect joint for epoxy shorts across the termination and micro strip gaps that would cause a
short across the cap.
Isopropanol, and Methanol are both safe to use to pre clean Milli-Caps®
They are not to be used after mounting with conductive epoxy as they act as a solvent!