 浏览型号XB24CZ7RIS-004的Datasheet PDF文件第27页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第28页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第29页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第30页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第32页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第33页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第34页浏览型号XB24CZ7RIS-004的Datasheet PDF文件第35页  
XBee®/XBeePRO® ZB SMT RF Modules  
When data is transmitted from one node to another, a network-level acknowledgement is transmitted back  
across the established route to the source node. This acknowledgement packet indicates to the source node that  
the data packet was received by the destination node. If a network acknowledgement is not received, the  
source node will re-transmit the data.  
It is possible in rare circumstances for the destination to receive a data packet, but for the source to not receive  
the network acknowledgment. In this case, the source will retransmit the data, which could cause the  
destination to receive the same data packet multiple times. The XBee modules do not filter out duplicate  
packets. The application should include provisions to address this potential issue  
See Data Transmission and Routing in chapter 4 for more information.  
Receive Mode  
If a valid RF packet is received, the data is transferred to the serial transmit buffer.  
Command Mode  
To modify or read RF Module parameters, the module must first enter into Command Mode - a state in which  
incoming serial characters are interpreted as commands. Command Mode is only available over the UART when  
not using the Smart Energy firmware. The API Mode section in Chapter 9 describes an alternate means for  
configuring modules which is available with the SPI and with Smart Energy, as well as over the UART with ZB  
code.  
AT Command Mode  
To Enter AT Command Mode:  
Send the 3-character command sequence “+++” and observe guard times before and after the com-  
mand characters. [Refer to the “Default AT Command Mode Sequence” below.]  
Default AT Command Mode Sequence (for transition to Command Mode):  
•No characters sent for one second [GT (Guard Times) parameter = 0x3E8]  
•Input three plus characters (“+++”) within one second [CC (Command Sequence Character) parame-  
ter = 0x2B.]  
•No characters sent for one second [GT (Guard Times) parameter = 0x3E8]  
Once the AT command mode sequence has been issued, the module sends an "OK\r" out the UART pad. The  
"OK\r" characters can be delayed if the module has not finished transmitting received serial data.  
When command mode has been entered, the command mode timer is started (CT command), and the  
module is able to receive AT commands on the UART port.  
All of the parameter values in the sequence can be modified to reflect user preferences.  
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. By default,  
the BD (Baud Rate) parameter = 3 (9600 bps).  
To Send AT Commands:  
Send AT commands and parameters using the syntax shown below.  
Syntax for sending AT Commands  
Carriage  
Return  
“AT”  
ASCII  
Space  
Parameter  
Prefix Command (optional) (optional, HEX)  
Example: ATDL 1F<CR>  
To read a parameter value stored in the RF module’s register, omit the parameter field.  
The preceding example would change the RF module Destination Address (Low) to “0x1F. To store the new  
value to non-volatile (long term) memory, subsequently send the WR (Write) command.  
© 2010 Digi International, Inc.  
31